New features in build 4.11.3.4160

A number of improvements were made to increase the stability of the system.

New features in Intellect 4.11.3

  1. Added the SET_FILTERS command to the Events protocol (EVENT_VIEWER), which can be used in scripts to filter out the events.

  2. Supported the TLS version 1.2 certificate in the Web-server.

  3. Added the START_VIDEO and STOP_VIDEO commands to the Video Gateway (GATE), which can be used in scripts to start and stop recording on the selected camera.

  4. In the dbo.OBJ_PERSON table of the main Intellect database, increased the character limit for visit_document from 120 to 255

  5. Added events to the Map (MAP):

    1. ACTIVATE_OBJECT—activation of the object. The event is received when an object is selected (activated by a single mouse click) on the Map.

    2. OBJDBLCLK—the event is received when you double-click on an object on the Map

  6. The configuration of a SIP-terminal can now be transferred to a backup server in case of the connection with the main server is lost (Failover service). To do this, specify the IP address of the backup server in the sip_terminal.config file. By default, the file is located in the <Intellect installation directory>\Modules folder

  7. Adjusted the name settings for the final export file in the Export period:

    1. if the Default file name checkbox is set, then the resulting file will have the name "<Camera and camera number><Date and time><Video episode number>.avi".

    2. if the Default file name checkbox is clear, then the file path becomes editable and you can set your own file name in it.

  8. Added the StatusInfo registry key, which enables the recording of detailed statistics (including statistics per camera) about the system every 10 seconds in the video.run log files.

  9. Introduced the new ArchProbe utility, which can help you check the integrity of video archive files recorded in the Intellect internal format. The utility is located in the <Intellect installation directory>\Tools folder and is launched in the Command line. In the utility, specify the path to the folder with archive records or to a specific recording. As a result, information on each recording of the specified video archive will be displayed.

  10. Now Axxon Player generates a text file AxxonPlayer.lh, which contains the log of video archive views via the Player

  11. Improved the window for adding multiple events to the Incident handler (the Add button on the Incident handler settings panel):

    1. all columns are now sorted alphabetically by default;

    2. added Autoescalation;

    3. added a column with an identifier to the Objects table.

IP device support

The release includes Drivers Pack 3.73.85 for IP devices support. Detailed information about the Drivers Pack, where to find the latest set of drivers, and the list of supported hardware is available at https://www.axxonsoft.com/integrated_security_solutions/supported-ip/

Updating from previous versions

Run the newer version installation program and install Intellect over the older version 4.11.2 or earlier. No need for uninstalling.

Product documentation

Requirements for base PCs

Updating INTELLECT™ software

Quick Start Guide

Complete Intellect Documentation

  • No labels