Go to documentation repository
Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.
The settings panel of the Charts object is shown in the figure.
Table describes the setting parameters of the Charts interface object.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
The Filters tab | ||||||
1 | Identification number | Automatically | Displays the identification number of the Charts interface object in the system | Numbers, letters, periods, hyphen, dash and underscore | - | Depends on the number of the Charts objects in the system |
2 | Name | Enter the value into the field | Sets the name of the Charts object in the system | Latin, Cyrillic and service characters | Charts | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | Disable | Set the chechbox | Displays the state (enabled or disabled) of the Charts object in the system | Boolean type | Clear | Set—the Charts object is disabled and isn't used Clear—the Charts object is enabled and used |
4 | Display | Select the value from the list | Sets the Display parent object, to which the given Charts object belongs | Name of the Display objects registered in the system | Name of the Display parent object | Depends on the number of the Display objects in the system |
5 | X | Enter the value into the field | Sets the X coordinate in the horizontal axis for the upper left corner of the Charts interface window | % of the screen width | - | From 0 to M*100, where M is the number of the installed monitors |
Y | Enter the value into the field | Sets the Y coordinate in the vertical axis for the upper left corner of the Charts interface window | % of the screen height | - | From 0 to M*100, where M is the number of the installed monitors | |
6 | W | Enter the value into the field | Sets the width of the Charts interface window | % of the screen width | - | From 0 to M*100, where M is the number of the installed monitors |
H | Enter the value into the field | Sets the height of the Charts interface window | % of the screen width | - | From 0 to M*100, where M is the number of the installed monitors | |
7 | The × button | Click the button | Opens a test window set the position of the Charts window | - | - | - |
8 | Allow moving | Set the checkbox | Allows moving the Charts interface window manually | Boolean type | Clear | Set—allow moving the Charts interface window manually Clear—disable moving the Charts interface window manually |
9 | Monitor | Select the value from the list | Sets the number of the monitor in the system for which the coordinates are specified | Numbers of the monitors in OS | 1 | From 1 to 16 |
10 | Number | Select the value from the list | Sets the identifier of the Analog sensor object, the data from which should be displayed in the chart | Sequence of numbers | - | Depends on the Analog sensor objects in the system |
11 | Name | Select the value from the list | Sets the name of the Analog sensor object, the data from which should be displayed in the chart | Names of the Analog sensor objects | - | Depends on the Analog sensor objects in the system |
12 | Color | Select the value from the list | Sets the display color of the corresponding analog sensor on the chart in the Charts interface window | Color palette | Black | RGB color |
13 | Line width | Enter the value into the field | Sets the width of the line in the chart | Sequence of numbers | 5 | >0 |
14 | Number of pixels | Enter the value into the field | Sets the number of pixels to be displayed in the chart | Sequence of numbers | 0 | >=0 |