The Main tab.

 

The List of devices tab.

 

The Connection to external server tab.

 

The table describes the setting parameters of the PS-RTP Server system object.

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number

Automatically

Displays the identification number of the PS-RTP Server object in the system

Sequence of numbers

-

Depends on the number of the PS-RTP Server objects in the system

2

Name

Enter the value into the field

Sets the name of the PS-RTP Server object

Latin, Cyrillic and service characters

PS-RTP Server

A line containing a sequence of any characters (letters, digits, service characters except for the > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

Disable

Set the checkbox

Sets the state (disabled or enabled) of the PS-RTP Server object 

Boolean type

Clear

Set—the PS-RTP Server object is disabled and isn't used

Clear—the PS-RTP Server object is enabled and used

4

Computer

Select the value from the list

Sets the Computer parent object of the digital system with the distributed architecture to which the given PS-RTP Server object belongs

Names of the Computer objects registered in the system


The name of the Computer parent object

Depends on the number of the Computer objects in the digital video surveillance system with the distributed architecture

The Main tab

5

IP

Select the value from the list

Sets the IP address of the network interface using which the third-party software will control the devices registered in Intellect via the GB28181 protocol

IP address

Depends on the parameters of the network connection

Depends on the parameters and the number of the network connections

6

Port

Enter the value into the field

Number of the port through which the third-party software will be connected via the GB28181 protocol

Sequence of numbers

5060

065535

7

Transport

Select the value from the list

Transport protocol for the data transmission

Supported transport protocols

UDP

UDP, TCP

8

from

Enter the value into the field

Lower limit of the RTP port range

Sequence of numbers

-

065535

9

to

Enter the value into the field

Upper limit of the RTP port range

Sequence of numbers

-

065535

10Server IDAutomaticallyThe identifier of the Intellect Server that is used by the third-party software to connect to the RS-RTP Server via the GB28181 protocol ---

The List of devices tab

11

Type

Select the value from the list

The type of object to be controlled via the GB28181 protocol

Names of the types of objects in Intellect objects tree

-

Depends on the number of the objects created in Intellect objects tree


12

Name

Select the value from the list

The name of the object to be controlled via the GB28181 protocol

Names of the objects in Intellect objects tree

-

Depends on the number of the objects created in Intellect objects tree

13

Device ID

Automatically

The identifier of the device that will be used in the third-party software to control objects via the GB28181 protocol

-

-

-

The Connection to external server tab

14

External server connection

Set the checkbox

Defines if Intellect connects to the external supserver using the PS-RTP Server object via the GB28181 protocol

Boolean type

Clear

Setthe external server connection is enabled

Clearthe external server connection is disabled

15

IP

Enter the value into the field

IP address of the supserver

IP address

-

000.000.000.000 – 255.255.255.255

16

Port

Enter the value into the field

Port used to connect to the external server

Sequence of numbers

5060

065535

17

Transport

Select the value from the list

Transport protocol used to connect to the external server

Supported transport protocols

-

TCP, UPD

18

Password

Enter the value into the field

Password used to connect to the external server

Latin, Cyrillic and service characters

-

A line containing a sequence of any characters

19LoginEnter the value into the fieldUsername used to connect to the external serverLatin, Cyrillic and service characters-A line containing a sequence of any characters

20

Server ID

Enter the value into the field

The identifier of the supserver via the GB28181 protocol

Sequence of numbers

-

00000000000000000000 99999999999999999999