Go to documentation repository
Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.
Attention!
The PS-RTP Server object was excluded from Intellect since the version 4.11.3.
The settings panel of the PS-RTP Server object is shown in the figures.
The Main tab.
The List of devices tab.
The Connection to external server tab.
The table describes the setting parameters of the PS-RTP Server system object.
№ | Parameter | Method of setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | Identification number | Automatically | Displays the identification number of the PS-RTP Server object in the system | Sequence of numbers | - | Depends on the number of the PS-RTP Server objects in the system |
2 | Name | Enter the value into the field | Sets the name of the PS-RTP Server object | Latin, Cyrillic and service characters | PS-RTP Server | A line containing a sequence of any characters (letters, digits, service characters except for the > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | Disable | Set the checkbox | Sets the state (disabled or enabled) of the PS-RTP Server object | Boolean type | Clear | Set—the PS-RTP Server object is disabled and isn't used Clear—the PS-RTP Server object is enabled and used |
4 | Computer | Select the value from the list | Sets the Computer parent object of the digital system with the distributed architecture to which the given PS-RTP Server object belongs | Names of the Computer objects registered in the system | The name of the Computer parent object | Depends on the number of the Computer objects in the digital video surveillance system with the distributed architecture |
The Main tab | ||||||
5 | IP | Select the value from the list | Sets the IP address of the network interface using which the third-party software will control the devices registered in Intellect via the GB28181 protocol | IP address | Depends on the parameters of the network connection | Depends on the parameters and the number of the network connections |
6 | Port | Enter the value into the field | Number of the port through which the third-party software will be connected via the GB28181 protocol | Sequence of numbers | 5060 | 0–65535 |
7 | Transport | Select the value from the list | Transport protocol for the data transmission | Supported transport protocols | UDP | UDP, TCP |
8 | from | Enter the value into the field | Lower limit of the RTP port range | Sequence of numbers | - | 0–65535 |
9 | to | Enter the value into the field | Upper limit of the RTP port range | Sequence of numbers | - | 0–65535 |
10 | Server ID | Automatically | The identifier of the Intellect Server that is used by the third-party software to connect to the RS-RTP Server via the GB28181 protocol | - | - | - |
The List of devices tab | ||||||
11 | Type | Select the value from the list | The type of object to be controlled via the GB28181 protocol | Names of the types of objects in Intellect objects tree | - | Depends on the number of the objects created in Intellect objects tree |
12 | Name | Select the value from the list | The name of the object to be controlled via the GB28181 protocol | Names of the objects in Intellect objects tree | - | Depends on the number of the objects created in Intellect objects tree |
13 | Device ID | Automatically | The identifier of the device that will be used in the third-party software to control objects via the GB28181 protocol | - | - | - |
The Connection to external server tab | ||||||
14 | External server connection | Set the checkbox | Defines if Intellect connects to the external supserver using the PS-RTP Server object via the GB28181 protocol | Boolean type | Clear | Set—the external server connection is enabled Clear—the external server connection is disabled |
15 | IP | Enter the value into the field | IP address of the supserver | IP address | - | 000.000.000.000 – 255.255.255.255 |
16 | Port | Enter the value into the field | Port used to connect to the external server | Sequence of numbers | 5060 | 0–65535 |
17 | Transport | Select the value from the list | Transport protocol used to connect to the external server | Supported transport protocols | - | TCP, UPD |
18 | Password | Enter the value into the field | Password used to connect to the external server | Latin, Cyrillic and service characters | - | A line containing a sequence of any characters |
19 | Login | Enter the value into the field | Username used to connect to the external server | Latin, Cyrillic and service characters | - | A line containing a sequence of any characters |
20 | Server ID | Enter the value into the field | The identifier of the supserver via the GB28181 protocol | Sequence of numbers | - | 00000000000000000000 – 99999999999999999999 |