Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.

Previous page The Settings panel of the Macro object  The Settings panel of the Time schedule object Next page


The Program object is used to create specialized programs in the embedded programming environment of Intellect.

The settings panel of the Program object is shown in the figure.

 

Table describes the setting parameters corresponding to the elements of the settings panel of the Program object.

 

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Program object in the video surveillance system

Numbers, letters, periods, hyphen, dash and underscore

-

Depends on the number of the Program objects in the digital video surveillance system with distributed architecture

2

Name*

Enter the value into the field

Sets the name of the Program object

Latin, Cyrillic and service characters

Program

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

Disable

Set the checkbox

Sets the state (enabled or disabled) of the Program object

Boolean type

Clear

Setthe Program object is disabled and isn't used

Clearthe Program object is enabled and used

4

Time zone

Select the value from the list

Sets the time period during which the given program operates

Names of the Time zone registered in the system

Never

Neverthis program will never be executed

Alwaysthis program is always in the state of execution

List of the created time zonesthe program will be executed within a pre-defined time period

The Computers group

5

Select an element*

Set the checkbox

Sets the computer on which the given program will be executed

Boolean type

Clear

Setthe program will be executed on the specified computer

Clearthe program will not be executed on the computer

6

Computer

Automatically

Sets the name of the computer in the local network

Computer name in the local network

Computer name in the local network

A line containing a sequence of any characters (letters, digits, service characters), case-insensitive.

Number of characters60

7

Name

Automatically

Sets the name of the computer

Name of the Computer object registered in the system

Name of the Computer object registered in the system

A line containing a sequence of any characters (letters, digits, service characters), case-insensitive.

Number of characters60

Not in group

8

Text editor*

Enter the value into the field

Used to enter the text of the program that should be executed

Latin, Cyrillic and service characters, digits

Not defined

A line containing a sequence of any characters (letters, digits, service characters), case-insensitive.

Unlimited number of characters

*Name of the element isn't displayed in the settings panel of the given object.

  • No labels