Go to documentation repository
Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.
The settings panel of the Scene interface object is shown in the figure.
Table describes the elements of the settings panel of the Scene object.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | Identification number | Automatically | Displays the identification number of the Scene object in the system | Numbers, letters, periods, hyphen, dash and underscore | - | Depends on the number of the Scene object in the system |
2 | Name | Enter the value into the field | Sets the name of the Scene object in the system | Latin, Cyrillic and service characters | Scene | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | Disable | Set the checkbox | Sets the state (enabled or disabled) of the Scene object in the system | Boolean type | Clear | Set—the Scene object is disabled and isn't used Clear—the Scene object is enabled and used |
4 | Display | Select the value from the list | Sets the Display parent object, to which the given Scene object belongs | Name of the Display objects registered in the system | Name of the Display parent object | Depends on the number of the Display objects in the system |
5 | Monitor | Select the value from the list | Used to select the Video surveillance monitor, on which the panoramic surveillance window should be displayed | Sequence of numbers | 1 | 1..9 |
6 | X | Enter the value into the field | Sets the X coordinate in the horizontal axis for the upper left corner of the Scene interface window | % of the screen width | - | From 0 to 100 |
7 | Y | Enter the value into the field | Sets the Y coordinate in the vertical axis for the upper left corner of the Scene interface window | % of the screen height | - | From 0 to 100 |
8 | W | Enter the value into the field | Sets the width of the of the Scene interface window | % of the screen width | - | From 0 to 100 |
9 | H | Enter the value into the field. | Sets the height of the Scene interface window | % of the screen width | - | From 0 to 100 |
10 | Number | Select the value from the list | Sets the number of the camera that should be displayed | Sequence of numbers | - | Depends on the number of the cameras registered in the system |
11 | Camera | Select the value from the list | Sets the name of the camera that should be displayed | Names of the cameras registered in the system | - | Depends on the number of the cameras registered in the system |
12 | fps | Select the value from the list | Sets the fps of the video signal that is transmitted to the Scene interface window | Sequence of numbers | - | 1, 2, 3, 4, 6, 8, 12, 16, 20, 25, 30 |
13 | Compression | Select the value from the list | Sets the compression level of the video signal that is transmitted to the Scene interface window. When the value is specified, the additional consumption of the Server resources occurs | Sequence of numbers | - | In order of increasing the compression level 0, 1, 2, 3, 4, 5 0—no compression 5—maximum compression |
14 | Gate | Select the value from the list | Sets the Videogate object, from which the video archive and video image from the selected camera should be transmitted to the Scene interface window | Names of the Videogate objects registered in the system | - | Depends on the number of the Videogate objects registered in the system |
15 | Range | Click the button | Access to complex selection and editing of the cameras parameters that should be displayed in Scene object window | - | - | - |
16 | All | Click the button | Selects all cameras registered in the system to be displayed in the Scene object window | - | - | - |