Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.

Previous page The Programming tab  The Settings panel of the Macro object Next page


The Security zone object is used for the general configuration of Intellect.

The settings panel of the Security zone object is shown in the figures.

The Basic settings tab.

 

The RabbitMQ tab.

Table describes the setting parameters corresponding to the elements of the settings panel of the Security zone object.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

The Settings group

1Protocol clear timeEnter the value into the field using the up and down buttonsSets the time of the day at which to start cleaning up the Event Viewer database according to the Events archive length parameterHH:MM:SSCurrent system time at the moment of the object setting panel opening00:00:00 to 23:59:59

2

Events archive length____days

Enter the value into the field

Sets the number of days to store information about the events registered by Intellect and recorded into both the Event Viewer and the Incident server. This parameter affects all computers in a distributed system

Days

3

Not less than 0

3

Object code

Enter the value into the field

Sets the number of the access control card, which is automatically displayed in the settings panel of the User object, when the object is created in the Object code field

Sequence of numbers

Not defined

More than 1

4

Starting configuration

Select the value from the list

Sets the macro, which will be automatically launched at Intellect start

Names of the Macro objects registered in the system

Not defined

Depends on the number of the Macro objects created in the digital video surveillance system with distributed architecture

5

Connections in architecture

Set the checkbox

Sets the computers with which the created Computer object should exchange the data about the system configuration parameters: with all computers in the digital video surveillance system with distributed architecture or only with the Computer object on the basis of which the given object was created

Boolean type

Clear

Setwhen creating a new computer, the Connection checkboxes in the Architecture tab are set for all computers in the architecture

Clearwhen creating a new computer, the Connection checkbox in the Architecture tab is set only for the computer on which this new object is created

6

DNS instead of IP allowed

Set the checkbox

Sets the address of the Server/Remote Administrator’s workstation/Remote Client in the Architecture tab as DNS name, not only IP address

Boolean type

Clear

Set—when configuring the interaction of the computers in the distributed system, DNS name (instead of IP address) of the Server/Remote Administrator’s workstation/Remote Client can be specified in the Architecture tab

Clear—when configuring the interaction of the computers in the distributed system, IP address of the Server/Remote Administrator’s workstation/Remote Client should be specified in the Architecture tab

7Ping (sec)Enter the value into the field

Sets the check period for the computer connection to the Server

Sequence of numbers10>=1
8Show documentation by clicking F1Set the checkboxEnables opening documentation in the pdf format by pressing F1, when Intellect is started. Administrator's Guide is opened on the Server and the Remote Administrator’s workstation; Operator's Guide is opened on the Remote ClientBoolean typeClear

Set—the documentation is displayed by pressing F1

Clear—the feature of displaying the documentation by pressing F1 is disabled

9Debug statisticsClick the buttonOpens the window with the events queue statistics---
10Administrator’s passwordClick the buttonOpen a dialog box for setting the Administrator’s password---

The Internal synchronization group

11

offline

Set the checkbox

Enables the offline synchronization of the events

Boolean type

Set

Set—the offline synchronization is enabled. When the computer is reconnected, it gets all the events for the period when there was no connection

Clear—the offline synchronization is disabled. When the computer is reconnected, it does not get the events for the period when there was no connection

12

online

Set the checkbox

Enables the online synchronization of the events

Boolean type

Set

Set—the online synchronization is enabled. The events are sent right after they occur according to the configuration parameters of the computer interaction in the distributed system

Clear—the online synchronization is disabled. The events are not sent

The Holidays group

13

Date*

-

List of calendar days which will be defined as holidays in Intellect

Date

Not defined

Date format: DD-MM-YY

14

Add

Click the button

Opens the Calendar dialog box to set the date of a new holiday

-

-

-

15

Delete

Click the button

Deletes the selected holiday date from the Date list

-

-

-

16

Edit

Click the button

Opens the Calendar dialog box to change the date of the selected holiday in the list

-

-

-

SMS confirmation
17SMS confirmationEnter the value into the fieldSets the Short Message object for two-factor authentication—see Configuring two-factor authenticationNames of the Short Message objects registered in the systemNot definedDepends on the number of the Short Message objects created in the system
The RabbitMQ tab
18ServerEnter the value into the fieldSets the RabbitMQ host addressLatin characters, digits and service characterslocalhostHost IP address or name
19PortEnter the value into the fieldSets the RabbitMQ host portLatin characters, digits and service charactersNot defined

0–65535

If the port is 0 or not specified, RabbitMQ won't run

20UserEnter the value into the fieldSets the RabbitMQ host user nameLatin characters, digits and service charactersguestDepends on the registered RabbitMQ users
21PasswordEnter the value into the fieldSets the RabbitMQ host user passwordLatin characters, digits and service charactersguestDepends on the registered RabbitMQ users
22Content-typeSelect the value from the listSets the type of the sent/received contentSupported types of contentplain/text

application/json—a message in JSON format is sent

plain/text—Intellect event is sent in the following format: "TYPE|ID|EVENT"

*Name of the element isn't displayed in the settings panel of the given object.