The Windows section is used to set Windows running Windows OS. The settings panel for the Windows section is shown in the figure.
The parameters of the Windows setting panel are described in the table.
No | Parameter name | Field type | Description | Representation | Default value | Value range |
The Shell group | ||||||
1 | The Explorer/ | Set in the position | Selection of Windows working shell Attention! Disable UAC to run the Intellect software package as the shell. Configuration of the local security policy is required for full disabling of UAC in the Windows 8 and Windows 8.1 OS – see OS settings for correct operation of Remote Admin Workstation or Server | - | Explorer | Explorer – Microsoft Explorer is loaded as working Windows OS shell (corresponds to standard Windows OS settings) File – Intellect starts as a working shell of Windows OS. |
2 | The File field with button. Active for the File switch position | Button is pressed | Opens standard Windows window «Open» to select shell file of OS Windows. Full path to the file is displayed in the field.
| - | - | The intellect.exe or slave.exe executive file is selected as a shell |
The Autologon group | ||||||
3 | The Enable checkbox | Checkbox | Activates automatic log on of the user to OS Windows | Boolean type | No | Yes – automatic log on of the user is activated No– automatic log on of the user is not activated
|
4 | The Username field | Type-in the value | Set the username for logging on the OS Windows | - | - | Up to 64 characters. Depends on the settings of Windows user account (stored locally or on domain server) |
5 | The Password field | Type-in the value | Set the password for logging on the OS Windows | - | - | 8 to 14 characters Depends on the settings of Window’s user account (stored locally or on domain server) |
6 | The Domain field | Automatically | Displays the name of domain server (if there is any), where data concerning user account is stored (user name and password) | - | - | Depends on domain net settings (net settings of OS Windows correspondingly) |
7 | Restart Intellect on user login checkbox
| Setting checkbox | Specifies the way of restart the Intellect software installed as a service on user login
| Boolean type | Yes | Yes - the Intellect software installed as a service restarts under the current user if it belongs to the IntellectUsers group. No - The Intellect software installed as a service doesn't restart under the current user even for users belonging to the IntellectUsers group. |