Go to documentation repository
The “GAI-Tronics HelpPoint” SIP-device is configured through the Web-interface the following way:
Specify parameters of SIP protocol on the “SIP Settings” tab.
№ | Parameter | Parameter value | Information | |
1 | LOCALID | Sequence of symbols (letters, digits etc.) | User ID for connecting to the SIP-device | |
2 | PROXY | Empty field | Proxy-server is not in use | Call from the SIP-device readdresses directly to the Intercom Subsystem Server |
3 | REGISTRAR | Empty field | Readdress Server is not in use | |
4 | USERNAME | Sequence of symbols (letters, digits etc.) | User name of SIP-device. Should coincide with “LOCALID” parameter value | |
5 | PASSWORD | Sequence of symbols (letters, digits etc.) | Password to connect to the SIP-device | |
6 | ENDPOINT | ENABLED | SIP-device activated |
Add the Intercom Subsystem Server of security intercom terminals to the contact list of SIP-device on page 1 «Memories & Comfort Strings» of the «Dialing & Memories» tab.
№ | Parameter | Parameter value | Information |
1 | MEMORY | sip:<name>@<IP address> | SIP URL consists of two parts: <name> -user name. It is ignored while calling <IP address> - IP-address of Intercom Subsystem Server |
2 | COMFORT | Sequence of numbers | Use to configure calls addressing from SIP-device (see step 4) |
Set the call direction while clicking the call button on page 2 «Memory Lists» of the «Dialing & Memories» tab.
№ | Parameter | Parameter value | Information |
1 | Number | Sequence of numbers | Number of required call button |
2 | WAKEANDIAL | ON | Includes the call addressing to the Intercom Subsystem Server while clicking the required button |
3 | LIST | Sequence of numbers | Should coincide with “COMFORT” parameter value, corresponding to the SIP URL of required Intercom Subsystem Server (see step 3). |
Configuring of the «GAI-Tronics HelpPoint» SIP-device through the Web-interface is completed.