Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page Connecting sensors MO USBIO 4x4  Configuring AGRG-IO-16/8-WD-DS Sensor-Relay cards Next page


If relays are connected to the Server via IP devices, then select the corresponding type of IP device on the settings panel of the Video Capture Device object; set IP address, name and password in order to connect to camera (see Configuring IP devices section).

Note

If relays are connected to the Server via Bosh IP device, then specify the service value in the Name field. With another value the functionality of the relay is not performed on the Server.

If Smartec STS-IPT-880 IP server is in use, then sensors are to be connected to those channels for which the Camera objects are created. Channel with N number corresponds to 2 sensor channels with 2N-1 and 2N numbers.

Note

Smartec STS-IPT-880 IP Server supports up to 8 video channels and 16 sensors (2 sensors for each channel).

To connect each pair of sensors create the Camera object with N channel number, then create two Sensor objects with 2N-1 and 2N channel numbers. The Camera and Sensor objects are created under one Video Capture Device object of the Smartec type. If sensors are connected via inactive video channel (no Camera object), then the functionality of sensora is not performed on the Server.

To implement the functionality of sensors connected via AEBELL BL-E704F IP server disable the Auto Work Plan mode. This mode is enabled/disabled via Web interface of IP server or in the dialog box of the Network DVR Monitor System utility (see the reference documentation on IP server).