The function of creating events using the Operator protocol allows generating alarm events manually. This function is used, for example, when the event in the frame was not detected by standard means but is to be in the archive.

There is Created by Operator message in the Initial Event column when displaying events created this way (see Search in events archive).

To create an event, do the following:

  1. Go to the Create event tab of the Operator protocol.

  2. Type in the event description in the Comment.

  3. Click the Date/Time button and specify the date and time of the event in the opened box.

  4. Select the object type in the Type dropdown list.
  5. In the Object drop-down list, select the object which registered the event.
  6. Click the Create button.

The event of the Alarm situation type will be added to the archive.

Note.

In order to view the video recording on the event created by the Operator, one is to start recording on the required camera manually (see Recording by Operator command section).

The event is now created.