Go to documentation repository
Note
Detailed description of the given devices can be found at https://www.stream-labs.com/products/
Automatic brightness control. In this mode Axxon PSIM automatically uses internal algorithm of image’s brightness control. This mode is enabled when the Brightness slider is set to a minimum position. When there are no special requirements to the image, then this mode of brightness control is recommended.
Note
Brightness can be controlled manually, moving the Brightness slider.
Note
The image will move through the second video input channel.
Video stream frame rate. When only one camera is connected to Wave Server Enterprise hardware internetwork, the video stream frame rate is 25 fps. When two or more cameras are connected, total frame rate of processed video is 16 fps.
Note
If two video input channels are used, then frame rate of processed video is 16/2=8 fps. If there are four video input channels, then 16/4=4 fps
Note
For every analog camera connected to Wave Server Enterprise, two Camera objects are to be created under different Video Capture Device objects for video viewing and telemetry configuration correspondingly.
Telemetry. When telemetry for Wave Server WH1501 video server is configured, it is necessary to select protocol with the help of which the analog camera connected to the video server is controlled, on the settings panel of the Telemetry control object (for example, Pelco-D, Pelco-P, Panasonic-850).