Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page SIP_TERMINAL SIP-terminal  INC_SERVER Incident server Next page


The INC_MANAGER object corresponds to the Incident manager system object.

The INC_MANAGER object sends events given in the tableProcedures are started when the corresponding event occurs.

EventsEvents descriptionParemetersParameters descriptionComment

CLOSE_CLICK

Click the Close button in the interface

The event is generated when an incident is closed without being processed by the operator in the Incident manager interface
CLOSE_ALL_CLICKClick the Close all button in the interface

The event is generated when all incidents are closed without being processed by the operator in the Incident manager interface

SELECT

Click an incident in the interface

The event is generated if the operator left-clicks or right-clicks the incident in the Incident manager interface
ACTIVATE_EVENT


The operator selected the event (click the event with the mouse) 


alarm_time<>Time when the event occurred
event_guid<>Event ID (generated randomly for each event)
objtype<>Object type (for example, CAM, GRELE, and so on)

action<>

Action type (for example, MD_START, DISARM, and so on)


  • No labels