One can configure video subsystem automatically in Axxon PSIM™ software using the initial configuration wizard.

Attention!

The initial configuration wizard is not available if at least on of the following conditions is met:

  1. Axxon PSIM software runs in Demo mode.
  2. Video capture card or Audio card object(s) has already been created in Axxon PSIM software.
  3. Axxon PSIM Server is configured from other Server in the distributed architecture.

Configure the video subsystem automatically as follows:

  1. Go to the Hardware tab in the System settings dialog box (1).
  2. Select the Computer object related to the required Server in the object tree in the Hardware tab (2).
  3. Click the Initial configuration wizard button on the settings panel of the selected object (3).

  4. The Creating initial configuration of the video subsystem window is displayed.

  5. To create initial configuration of the video subsystem, click the OK button. This action will add objects based on Axxon PSIM software key.

  6. As a result, the created objects are displayed in the object tree.


    Note

    The following objects are created as a result of initial configuration wizard working

    1. The Video Capture Device objects (specified in the key) that correspond to the physical video capture cards (for example, 4 Video Capture Device objects are created for one FS6/16 video capture card);
    2. The Camera objects - one for each Video Capture Device object;
    3. The Audio card object configured to work with a local audio card;
    4. The Microphone objects under the Audio card object (the number of the Microphone objects is equal to the number of audio channels in the key).

    Initial configuration wizard does not create other objects that are given in the key.