Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page The Settings panel of the MSDE (MS SQL) configuration section  The Settings panel of the Testing video capture cards section Next page


The Video subsystem section is used for advanced configuration of the video subsystem in order to enhance the performance of Axxon PSIM.

The settings panel for the Video subsystem section is shown in the figure.

The parameters of the settings panel are described in the table.

No

Parameter name

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

1

Ring

Enter the value in the field

Sets free disk space; when the limit is reached, the earliest recordings will be deleted on loop (see General information on video archiving). If two or more disks are used for video archiving, archiving on current disk is performed till there is FreeMbCritical of free disk space (1000 MB by default, see the info on the key in Registry keys reference guide).

Free space set by the Ring parameter is used for recording temporary files. This means that when the limit set by the Ring parameter is reached, the maximum size of the temporary file is Ring (registry key FreeMb). Video can contain less frames than set by the Frame count parameter.

Note. Old recordings may get deleted before the remaining disk space reaches the specified value if the disk space is less than 15000

MB

5000

Depends on the hard disk space


2

Frame count

Enter the value in the field

Sets the maximum number of frames in one recording file

Frame

1500

1500 to 10000. We don't recommend changing the default value

3

Recording time

Enter the value in the field/select the value from the list

Sets the length of the file in seconds, restricting fragment’s size not by number of frames, but by time of its recording

Time in seconds

0

Unlimited

4

Restart recording on entering the archive

Enter the value in the field/select the value from the list

Enables the restart of recording on entering the archive

Integer

No

0—video fragment that was being recorded at the moment of entering the archive is forcibly stopped, and a new one starts. As a result, the user who enters the archive sees a freeze frame corresponding to the moment of entry

>0the recording is restarted when entering the archive, while positioning in the archive is carried out with a shift back to the specified value in seconds

-1recording is not stopped at the moment of entering the archive

5

Rebuild index

Click the button

Deletes the file that stores indexes. After deleting the file, click the Rebuild index button to restart Axxon PSIM and create a new file with updated indexes

-

-

-

6

Priority

Select the value from the drop-down list

Sets the execution priority of all Axxon PSIM processes

Names of priority processes

Below normal

Realtime, High, Above normal, Normal, Below normal, Low


7

Analog video output

Select the value from the drop-down list

Selects the operation mode of the analog output

Names of available modes

All

Allvideo signal from a camera is displayed on a separate analog monitor

Onevideo signals from cameras that are connected to different video capture devices, are displayed on a separate analog monitor

8

Use virtual grabber

Set the checkbox

Allows access to virtual Video capture devices settings in Axxon PSIM.

Note. Desktop Experience Feature must be enabled when using a virtual video capture device on server OS and avi files

 

Boolean type

Clear

Setthe Virtual and Virtual bench values are available from the Type drop-down list on the settings panel of the Video capture device objects

Clearthe Virtual and Virtual bench values aren't available for the Video capture device objects

9

Hide mask

Set the checkbox

Disables displaying the video hidden by the motion detection mask. Video area marked by motion detection mask will be hidden by a grey fill. This feature works only on uncompressed video from FS or FX local video capture cards

Boolean type

Clear

Clearvideo hidden by the mask is displayed

Setvideo hidden by the mask video isn't displayed

10Automatic font size selection for exportSet the checkboxEnables the relative font size for captions (camera No. and time) when exporting a frame or fragments of the video archiveBoolean typeClear

Clearwhen exporting a frame, regardless of the video resolution, the caption size remains constant as set by the SubtitlesFontSize registry key, see the Registry keys reference guide

Setwhen exporting a frame, the caption size is scaled depending on the video resolution

11Gradual increment of camera tileSet the checkboxEnables a gradual increase of the Surveillance window on the custom layout by double-clicking the left mouse button. All Surveillance windows on the layout must be of the same size to ensure proper operation of the keyBoolean typeClear

Clear—Surveillance window is expanded to the entire Video surveillance monitor by double-clicking the left mouse button

Setby double-clicking the left mouse button, the Surveillance window is expanded gradually: the first double-click expands it two times of the initial size, the second double-click expands it three times of the initial size, and so on. The Surveillance windows adjacent to it are hidden on the layout

12

Swap frame fields

Set the checkbox

Switches Axxon PSIM from basic to additional driver if there are video artifacts when using the basic driver

Boolean type

Clear

ClearAxxon PSIM operates with basic driver

SetAxxon PSIM operates with additional driver

13

Use PureVideo/CUDA hardware acceleration

Set the checkbox

Enables PureVideo/CUDA support on the Server when decompressing video from IP devices if PureVideo HD card of the second or third generation (NVIDIA VP2 and VP3) is installed. Used to reduce CPU load due to resources of graphics processor

Boolean type

Set

ClearPureVideo/CUDA isn't used

SetPureVideo/CUDA is used

14

Pause playback at archive entry

Set the checkbox

The Pause button is clicked when entering the archive

Boolean type

Clear

Setthe Pause button is clicked when entering the archive, you can navigate through the archive using arrow keys

Clearthe Pause button isn't clicked when entering the archive

15

Step of digital zoom scale

Enter the value in the field/select the value from the list

Specifies the fractional step of video image zooming

Numbers with the fixed point

2.00

Maximum value depends on the maximum scale of digital zoom (see 17).

Minimum value is 1.00

16

Maximum ratio of digital zoom

Enter the value in the field/select the value from the list

Specifies the maximum value of digital zoom of video image

Numbers

16

116

17

Cameras without video compression 

Enter the value in the field

Specifies the numbers of cameras connected to the video capture cards with compression. There is no compression for these cameras, i.e. the compressor settings in Axxon PSIM are ignored

Camera serial number

-

Depends on the number of cameras registered in the system

 

Note

 Setting the non-zero value to the Recording time parameter does not disable the Frame count parameter. If the values for both parameters are set, then the file recording will be performed in accordance with the value which comes first. For instance, if the value of Recording time is equal to 10 seconds and Frame count is equal to 500 frames (by default) and in 10 seconds the fragment consists of 80 frames, then 80-frame file will be recorded. 
  • No labels