Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page GRAY Sensor  SMS Short Message Service Next page


The VNS object corresponds to the Voice notification service system object.

List of commands and parameters for the VNS object is presented in the table:

Commandcommand description

Parameters

Description

"SETUP"settings of the voice notification service

card<>

Name of sound device.

Note. Card name must correspond to the name specified in the settings of the sound card of the Voice notification service

level<>

Level of signal. The value of the parameter varies from 0 to 15. By default, it is 8

channel<>

Set of sound channels. Possible values of the parameter: 0no sound channel; 1left playback channel; 2right playback channel; 3left and right playback channels (both channels)

flags<>

Flags

ip<>

IP-address of network device

name<>

Object name

pass<>

Password

user<>

Username

"PLAY"play audio file

file<>

Full path to the audio file in .wav format (indicating the name of the file being played. For example: C:\Program Files (x86)\Axxon PSIM\Wav\cam_alarm_1.wav).

Note. If only file name is specified, the default path to the file will be taken from the InstallPath registry key in the HKEY_LOCAL_MACHINE\SOFTWARE\AxxonSoft\PSIM section (HKEY_LOCAL_MACHINE \Software\Wow6432Node\AxxonSoft\PSIM for 64-bits system), in value of the InstallPath parameter. In this parameter, it is possible to play several audio files using the "+" operation

"STOP"stop playing audio file--

Properties of the VNS object are shown in the table.

Properties of the VNS object

Description of properties

ID<>

Object ID

PARENT_ID<>

Parent object ID