Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page Restoring changed creation dates using the Convert.exe utility  The SignCheck.exe utility for checking the authenticity of exported frames Next page


One can work with the Convert.exe utility using Windows command prompt. The following startup parameters are in use:

  1. TZ +hh:mm – changing date of file creation and modification for hh hours and mm minutes.
  2. PATH – specifies the path to the archive folder with files date of creation (modification) of which is to be restored.
  3. FULLMODE – running the utility in order to correct the date of creation and modification.
  4. FORMAT is similar to FULLMODE. It also converts archive files to a format optimized for high-resolution archiving. The execution time of the FORMAT operation is comparable the the time required for a full conversion of the archive on the disk, because it requires reading every frame and creating a backup copy of the files while they are being converted. After the format of the archive or record has been updated, the execution time of subsequent conversions in FULLMODE will become the same as during an ordinary conversion.

Examples of commands for working with the Convert.exe utility using the command prompt:

  1. Convert.exe PATH "H:\Video\03-09-12 15" FULLMODE
    Running this command the Convert.exe utility will restore the date of file creation and modification in H:\Video\03-09-12 15 folder.
  2. Convert.exe TZ +01:00
    Running this command the time of file creation and modification will change for an hour. For instance, the “17-09-12 13” folder will be renamed as “17-09-12 14”.

Note.

These examples assume using a command prompt in <Axxon PSIM>\ Tools folder.