Documentation for Axxon PSIM 2.0. Documentation for other versions of PSIM is available too.

Previous page Configuring archive synchronization of main and backup Servers  Configuring the SNMP-service Next page


On this page:

Licenses

The Failover mode is configured using the Failover service objects created on the basis of the Computer objects corresponding to backup servers in the Hardware tab of the System settings dialog box.

If the quantity of cameras is bound to specific Servers in the security key, then the license becomes invalid when cameras are moved to the backup Server. In this case the system gives 50 days to restore the failed Server in order to move the cameras back and the license to become valid again. Otherwise, Axxon PSIM will unload on the backup Server because the hardware limit is exceeded (see Specifics of the Axxon PSIM operation when the object limit is exceeded). The time (in days) remaining for restoring the main Server is displayed on the settings panel of the Failover service object:

Limitation on the number of simultaneously running Failover services

The number of failover services running on each computer simultaneously can be limited. The Manager of failover services object is used for this. It is created on the basis of the Computer object that is not the Client (see Role-assignment in distributed system).

If the number of failed Servers exceeds the specified limit, the configuration from the new failed Servers will be transferred to the corresponding backup Server as the previously failed Servers become operational.

Transferring vertical solution objects

You can find the links to documentation for vertical solutions on the AxxonSoft Documentation page.

The table shows the versions of vertical solutions compatible with Axxon PSIM 2.0. The availability of object transfer for the Auto and Face vertical solutions depends on the module used and the availability of a license for it.

Vertical solutionAvailability of module license keyModuleHow the Failover service works
Face PSIMNoVA SDK 20230804_r1

Objects are transferred correctly, face recognition continues. Images of recognized faces are sent to the "FaceDB" (default) folder

YesVisionLabs SDK 5.10.0

Objects are transferred correctly, face recognition stops. Images of recognized faces are sent to the "FaceDB" (default) folder

Auto PSIMNoRR

Objects are transferred correctly, vehicle recognition continues. Images of recognized vehicles are sent to the "LprDB" (default) folder

YesAUTO-Uragan moduleObjects are transferred correctly, vehicle recognition stops
YesVTObjects are transferred correctly, vehicle recognition stops
POS PSIMObjects are transferred correctly, receipt and title databases are not transferred
DetectorPack PSIM

Objects are transferred correctly, detection tools continue to work after transfer (they generate events when triggered)