Documentation for Axxon PSIM 2.0. Documentation for other versions of PSIM is available too.

Previous page Next page


On the page:

The settings panel of the Operator protocol interface object is shown in the figures. Tables below describe the setting parameters corresponding of the Operator protocol object.

The Filters tab

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number* field

Automatically

Displays the identification number of the Operator protocol object in the system

Numbers, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the Operator protocol objects in the system

2

The Name* field

Enter the value in the field

Sets the name of the Operator protocol object in the system

Latin alphabet, Cyrillic,numbers, and service characters

Operator protocol

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

The Disable checkbox

Set the checkbox

Disables the Operator protocol object in the system


Boolean type

Clear

Setthe Operator protocol object is disabled and isn't used

Clearthe Operator protocol object is enabled and used

4

The Display drop-down list

Select the value from the list

Sets the Display parent object for the given Operator protocol object

Names of the Display objects registered in the system

Name of the Display parent object

Depends on the number of the Display objects in the system

The Position group

5

The X field

Enter the value in the field

Sets the X coordinate in the horizontal axis for the upper left corner of the Operator protocol window

% of the screen width

50

From 0 to M*100, where M is the number of the installed monitors

The Y field

Enter the value in the field

Sets the Y coordinate in the vertical axis for the upper left corner of the Operator protocol window

% of the screen height

50

From 0 to M*100, where M is the number of the installed monitors

The W field

Enter the value in the field

Sets the width of the Operator protocol window

% of the screen width

50

From 0 to M*100, where M is the number of the installed monitors

The H field

Enter the value in the field

Sets the height of the Operator protocol window

% of the screen width

50

From 0 to M*100, where M is the number of the installed monitors

The Allow moving checkbox

Set the checkbox

Allows moving the Operator protocol window

Boolean type

Clear

Setallow moving the Operator protocol window using the mouse

Cleardisable moving the Operator protocol  window using the mouse

The  button

Click the button

Opens the template window to set the position of the Operator protocol window

NANANA
The Monitor drop-down listSelect the value from the listDetermines the number of the monitor in the system for which the coordinates are specifiedNumbers of the monitors in OS1From 1 to 16
6The Chief interfaces
checkbox
Set the checkbox

Sets the Operator protocol object, to which the events must be sent after the time specified by the Wait for operator response for parameter

List of the available Operator protocol objects in the systemNADepends on the number of the Operator protocol objects created in the system
7The Add events buttonClick the buttonOpens the window for bulk adding the events from an object of the selected typeNANANA
The Filters tab
The Objects table

8

The Type drop-down list

Select the value from the list

Sets the type of objects, the events from which must be displayed in the Operator protocol window


Available object types

NA

Depends on the objects registered in the system.

Only the objects for which the "INFORMATION" or "ALARM" value is selected in the Messages processing column on the Events tab in the ddi.exe utility are available for selection (see The Events tab)

The Number drop-down list

Select the value from the list

Sets the number of the object, which events must be displayed in the Operator protocol window

Sequence of numbers

NA

Depends on the number of the objects of the specified type registered in the system

The Name field

Automatically

Sets the name of the object, which events must be displayed in the Operator protocol window

Names of the objects registered in the system

NA

Depends on the objects registered in the system

The Event type drop-down list

Select the value from the list

Sets the events displayed in the Operator protocol window

Events available for the selected object

NA

Depends on the object type

The Request password drop-down list

Select the value from the list

Determines the necessity of a password to process the event

Boolean type

NA

Set—password confirmation is required to process the event

Clear—password confirmation isn't required to process the event

The Region drop-down list

Select the value from the list

Sets the Region object corresponding to the monitored object

List of the Region objects created in the system

NA

Depends on the number of the Region objects created in the system

The Parameter field

Enter the value in the field

Sets the parameter of the monitored object

Depends on the event type

NA

Depends on the event type

The Value fieldEnter the value in the fieldSets the parameter value of the monitored objectDepends on the event typeNADepends on the event type
The Help file fieldEnter the value in the fieldSets the full path to the text file in PDF, DOC, DOCX, TXT which contains the help guide about the event processingFile address in the file systemNAIn accordance with the file system limitations
The Priority drop-down listSelect the value from the listSets the event priority when sorting by importanceSequence of numbersNA

From 1 to 10.

The lower the value, the higher the priority

The Parameters table
9The Parameter fieldEnter the value in the field

Sets the name of the parameter, the value of which must be displayed in the Operator protocol window

Latin alphabet, Cyrillic, numbers, and service charactersNADepends on the parameters sent by the event

The Description field

Enter the value in the field

Enters a short description of the specified parameter

Latin alphabet, Cyrillic, numbers, and service characters

NA

From 0 to 255 characters

The Checklist table
10The Description fieldEnter the value in the fieldSets the description of the action that the operator must perform before assigning a status to the eventLatin alphabet, Cyrillic, numbers, and service charactersNAFrom 0 to 255 characters
Out of the group
11The Map drop-down listSelect the value from the listSets the Map object used to display the monitored objectList of the available Map objects in the systemNA

Depends on the number of the Map objects created in the system

12The Video drop-down listSelect the value from the listSets the method of the archive and live video display by the event in the operator protocolAvailable display methodsActiveX

ActiveXarchive opens in a separate window

Monitorarchive opens in the selected video surveillance monitor

13The Wait for operator response ____ minutes fieldEnter the value in the field

Sets the time after which the event is assigned the Non-processed event type or the event is escalated

Min2.500

From 0 to 10000.

Fractional values can be specified; integer and fractional parts are point-separated. For example, to set 2 minutes 30 seconds time period, enter 2.500

14The Store ____ events
field
Enter the value in the field

Enters the maximum number of events that can be displayed simultaneously in the list of the current events

Integer numbers 100Any integer starting from 0
15The Delay decision making for ____ minutes fieldEnter the value in the fieldSets the time for which the operator can delay the event processingMinNA

From 0 to 600.

  • The value isn't specified or 0the operator cannot delay the event processing;
  • Greater than 0the parameter sets the time for which the operator can delay the event processing;
  • Fractional values can be specified; integer and fractional parts are point-separated. For example, to set 2 minutes 30 seconds time period, enter 2.500

The Functions group*

16The Sort by priority
checkbox
Set the checkbox

Enables the sorting of events by priority.The descending sorting is performed in the following order:

  • Escalated, 
  • Alarm,
  • Information
  • Standard (the last three event parameters can be set in the DDI filesee The Events tab)
Boolean typeSet

Setsorting by priority is enabled

Clearsorting by order the events are received is enabled

The New events at the end checkboxSet the checkbox

Places new events at the end of the current events list

Boolean typeClear

Setnew event is placed at the end of the list

Clearnew event is added at the beginning of the list

The Close elsewhere checkboxSet the checkboxDeletes the event from other operator protocols after it is processed in one of the operator protocolsBoolean type Clear

Setwhen the event is processed in one of the operator protocols, it is deleted from other operator protocols

Clear—after the event is processed, it stays unprocessed in other operator protocols

The Password for closing checkboxSet the checkbox

Determines the necessity to enter the password to process the event 


Boolean type Clear

Set—the event processing must be confirmed with a password

Clearpassword isn't required for event processing

The Autoswitch checkbox

Set the checkbox

Enables autoswitch to the Current events tab of the Operator protocol window when a new event occurs

Boolean type

Clear

Setautoswitch is enabled

Clearautoswitch is disabled

The Autoactivation of last event checkboxSet the checkboxEnables the automatic cell activation of the last received eventBoolean typeClear

Setthe cell of the last received event is automatically activated

Clearwhen the event is received, the cell selected by the operator remains active

The Hide buttons for groups checkboxSet the checkboxHides the event processing buttons when a group of events is selectedBoolean typeClear

Setthe event processing buttons are displayed when a group of events is selected

Clearthe event processing buttons are hidden when a group of events is selected

The Clear comment checkboxSet the checkboxClears the comment field after the event is processed by the operatorBoolean typeClear

Setthe comment field is automatically cleared after the event is processed by the operator

Clearthe comment text remains in the comment field after the event is processed by the operator

The Fit window size checkboxSet the checkboxEnables the automatic resizing of the cell according to the Operator protocol windowBoolean typeClear

Setthe cell size is set equal to the size of the Operator protocol window area, that isn't occupied by the event control panel

Clearthe cell size is selected according to the content size

The Hide "Apply to all" checkboxSet the checkboxDisables the Apply to all buttonBoolean typeClear

Setthe Apply to all button is unavailable in the Operator protocol window, and the operator cannot process all events at once

Clearthe Apply to all button is available 

The Over all windows checkboxSet the checkboxEnables the operator protocol to be displayed over all windowsBoolean typeClear

Setthe Operator protocol window is displayed over all windows

Clearthe Operator protocol window is displayed in the standard mode

The Comment required checkboxSet the checkboxPrevents event processing without entering a commentBoolean typeClear

Setthe buttons for classifying the events (Alarm situation, Suspicious situation, False alarm) don't appear until the Comment field is filled

Clearthe operator can classify (process) the event without entering a comment

The Single selection
checkbox
 
Set the checkbox

Prevents the operator from selecting multiple events using the Shift and Ctrl keys

Boolean typeClear

Setthe operator cannot select multiple events using the Shift and Ctrl keys

Clearthe operator can select multiple events using the Shift and Ctrl keys

The DB tab

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range

1

The Server field

Enter the value in the field

Sets the name of the database server, in which the required database is stored

Latin alphabet, Cyrillic, numbers, and service characters

Name of the server used by the system

Depends on the number of servers in the system

2

The Folder 
field

Enter the value in the field

Sets the name of the database, in which the events must be stored

Latin alphabet, Cyrillic, numbers, and service characters

Name of the main database used by the system

Depends on the number of databases used by the system

3

The User field

Enter the value in the field

Sets the username for authorization in the database server

Latin alphabet, Cyrillic, numbers, and service characters

NANA

4

The Password
field

Enter the value in the field

Sets the password for authorization in the database server

Latin alphabet, Cyrillic, numbers, and service characters

NANA

5

The Connection dialog
button

Click the button

Opens the window of the database server connection

NA

NANA

The DB protocol tab

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range

1

The Server field

Enter the value in the field

Sets the name of the database server, in which the required Event Viewer database is stored (if it is extracted to a separate DB)

Latin alphabet, Cyrillic, numbers, and service characters

Name of the server used by the Event Viewer database (if it is extracted to a separate DB)

Depends on the number of servers in the system

2

The Folder field

Enter the value in the field

Sets the name of the Event Viewer database (if it is extracted to a separate DB), in which the events must be stored

Latin alphabet, Cyrillic, numbers, and service characters

Name of the Event Viewer database (if it is extracted to a separate DB) used by the system

Depends on the number of the Event Viewer databases used by the system

3

The User field

Enter the value in the field

Sets the username for authorization in the Event Viewer database server (if it is extracted to a separate DB)

Latin alphabet, Cyrillic, numbers, and service characters

NANA

4

The Password
field

Enter the value in the field

Sets the password for authorization in the Event Viewer database server (if it is extracted to a separate DB)

Latin alphabet, Cyrillic, numbers, and service characters

NANA

5

The Connection dialog
button

Click the button

Opens the window of Event Viewer database server connection (if it is extracted to a separate DB)

NA

NANA

The Interface tab

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
1The Frame drop-down listSelect the value from the listSets the frame color of the active cellColor paletteBlackRGB color
The Situation buttons group
2The Alarm field Enter the value in the fieldSets the name for the alarm assessing buttonLatin alphabet, Cyrillic, numbers, and service charactersNAFrom 0 to 255 characters
The Suspicious
field 
Enter the value in the fieldSets the name for the suspicious assessing buttonLatin alphabet, Cyrillic, numbers, and service charactersNAFrom 0 to 255 characters
The False
field 
Enter the value in the fieldSets the name for the false assessing buttonLatin alphabet, Cyrillic, numbers, and service charactersNAFrom 0 to 255 characters
3The Keyboard shortcut*
field
Press the key combinationSets the key shortcuts for the events assessmentKeyboard combinationsNone

You can combine the Ctrl, Alt and Shift keys with any other keys on the keyboard. For example, the Ctrl+Shift+Alt+A or the Ctrl+A shortcuts are allowed, but the D+A or D+Ins shortcuts aren't allowed, and so on

Out of the group
4The View
drop-down list
Select the value from the listSets the option of displaying events on the Current events tabAvailable display optionsoperator
  • operatorthe operator can select a full or a simple view on its own;
  • full: the events are displayed as cells with a screenshot;
  • simplethe events are displayed as lines without screenshots
5The Group by drop-down listSelect the value from the listSets the option of grouping events on the Current events tabAvailable grouping optionsoperator
  • operator: the operator can elect the grouping options on its own;
  • default: event grouping is disabled;
  • object: the events are grouped by object;
  • event: the events are grouped by event types;
  • region: the events are grouped by regions

*Name of the element isn't displayed in the settings panel of the given object

  • No labels