Documentation for Axxon PSIM 2.0. Documentation for other versions of Axxon PSIM is available too.

Previous page Next page


This tab contains the list of the system events that the selected object can generate. Each event is characterized by the set of parameters, and each of them you can edit:

  1. Name. The event identifier.
  2. Description. Short event description.
  3. Processing messages. Select the window to display the message about the event occurrence: alarm window or information window.
  4. Support audio. Attach .wav files for the event audio accompaniment.
  5. Disable network connection. The event can have the local range of action. If you set the checkbox, other computers in the network aren't notified about this event.
  6. Disable logging. By default, all events are displayed in the event log. Set the checkbox not to log the selected event and record it in the database.
  7. Windows log. Set the checkbox so that the logged event (see step 6) is recorded to the Windows event log. If the event isn't logged, then it cannot be logged to the Windows log.

Note

You can create only the events that are available for the selected object (created at the stage of the system programming). Initially all of them are in the main.ddi file.