Go to documentation repository
Previous page Next page
The settings panel of the System restart service system object is shown in the figure:
The table describes the setting parameters of the System restart service object.
№
| Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | Identification number* | Automatically | Displays the identification number of the System restart service object in the video surveillance system with the distributed architecture | Sequence of numbers | NA | From 1 and above. Depends on the number of the System restart service objects in the video surveillance system with the distributed architecture |
2 | Name* | Enter the value in the field | Sets the name of the System restart service object in the video surveillance system with the distributed architecture | Latin, Cyrillic, and service characters | System restart service | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | Disable | Set the checkbox | Disables the System restart service object in the system | Boolean type | Clear | Set—the System restart service object is disabled and isn't used Clear—the System restart service object is enabled and used |
4 | Computer | Select the value from the list | Sets the Computer parent object in the system to which the given System restart service object belongs | Name of the Computer objects registered in the system | Name of the Computer parent object | Name of the Computer parent object (you cannot edit the System restart service object remotely) |
5 | AxxonSoft USB Watchdog for PSIM_Host.exe | Set the checkbox | Activates the system of the automatic computer restart when the slave.exe. process isn't active | Boolean type | Clear | Set—the system of automatic restart is activated Clear—the system of automatic restart is deactivated |
Table of the performance monitoring of the Axxon PSIM modules | ||||||
6 | Module | Automatically | Displays the list of the modules running on the computer | Names of the running modules | NA | Depends on the number of the modules registered in the system |
7 | Status, hours | Automatically | Displays the current state of the modules | Names of the current states of the modules | NA |
Note. The module's run time since the last restart is displayed in the HH:MM:SS format in the square brackets |
8 | Response time, s | Enter the value in the field | Sets the time interval in seconds waiting for a response from the module. If there is no response after the specified time, you can restart the system | Non-negative integers | 60 | From 0 and above |
9 | Quantity of restarts | Enter the value in the field | Sets the maximal quantity of restarts for the time period specified in the In time and Type of period columns | Non-negative integers | 3 | From 0 and above |
10 | In time | Enter the value in the field | Sets the time period during which the maximum quantity of system restarts can be performed | Non-negative integers | 1 | From 0 and above |
11 | Type of period | Select the value from the list | Names of time period units | hours | hours—the time period is measured in hours days—the time period is measured in days | |
12 | Restart | Select the value from the list | Sets the type of system restart | Names of the possible restart types | none | none—restart isn't performed module—module restart is performed core—Axxon PSIM core restart is performed |
13 | Remains of restarts | Automatically | Displays the quantity of the remaining restarts for the time period specified in the In time and Type of period columns | Non-negative integers | NA | Depends on the maximum quantity of restarts and on the number of restarts that are performed for a current time period |
14 | Memory (Mb) | Enter the value in the field | Sets the module memory consumption threshold above which the module must be restarted | Non-negative integers | 0 | From 0 and above |
*Name of the element isn't displayed in the settings panel of the given object.