Documentation for Axxon PSIM 2.0. Documentation for other versions of PSIM is available too.

Previous page Next page


The settings panel of the System restart service system object is shown in the figure:

The table describes the setting parameters of the System restart service object.

 

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the System restart service object in the video surveillance system with the distributed architecture


Sequence of numbers

NA

From 1 and above.

Depends on the number of the System restart service objects in the video surveillance system with the distributed architecture



2

Name*

Enter the value in the field

Sets the name of the System restart service object in the video surveillance system with the distributed architecture



Latin, Cyrillic, and service characters

System restart service

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

Disable

Set the checkbox

Disables the System restart service object in the system


Boolean type

Clear

Setthe System restart service object is disabled and isn't used

Clearthe System restart service object is enabled and used

4

Computer

Select the value from the list

Sets the Computer parent object in the system to which the given System restart service object belongs


Name of the Computer objects registered in the system

Name of the Computer parent object

Name of the Computer parent object (you cannot edit the System restart service object remotely)

5

AxxonSoft USB Watchdog for PSIM_Host.exe

Set the checkbox

Activates the system of the automatic computer restart when the slave.exe. process isn't active

Boolean type

Clear

Setthe system of automatic restart is activated

Clearthe system of automatic restart is deactivated

Table of the performance monitoring of the Axxon PSIM modules

6

Module

Automatically

Displays the list of the modules running on the computer

Names of the running modules

NA

Depends on the number of the modules registered in the system

7

Status, hours

Automatically

Displays the current state of the modules

Names of the current states of the modules

NA

  • loaded—module runs;
  • unloaded (red field)no response from the module after the waiting time expires;
  • unloaded (no coloring)module is unloaded.

Note. The module's run time since the last restart is displayed in the HH:MM:SS format in the square brackets

8

Response time, s

Enter the value in the field

Sets the time interval in seconds waiting for a response from the module. If there is no response after the specified time, you can restart the system

Non-negative integers

60

From 0 and above

9

Quantity of restarts

Enter the value in the field

Sets the maximal quantity of restarts for the time period specified in the In time and Type of period columns

Non-negative integers

3

From 0 and above

10

In time

Enter the value in the field

Sets the time period during which the maximum quantity of system restarts can be performed

Non-negative integers

1

From 0 and above

11

Type of period

Select the value from the list

Names of time period units

hours

hoursthe time period is measured in hours

daysthe time period is measured in days

12

Restart

Select the value from the list

Sets the type of system restart

Names of the possible restart types

none

nonerestart isn't performed

modulemodule restart is performed

coreAxxon PSIM core restart is performed

13

Remains of restarts

Automatically

Displays the quantity of the remaining restarts for the time period specified in the In time and Type of period columns

Non-negative integers

NA

Depends on the maximum quantity of restarts and on the number of restarts that are performed for a current time period

14

Memory (Mb)

Enter the value in the field

Sets the module memory consumption threshold above which the module must be restarted

Non-negative integers

0

From 0 and above

*Name of the element isn't displayed in the settings panel of the given object.