Configure the Suprema RealScan control reader as follows:

  1. Connect the reader to a Server, download and install driver from the manufacturer's official web site.

  2. Create the Suprema RealScan object based on the Computer object on the Hardware tab of the System Settings dialog box.

  3. Uncheck the Automatic Calibrate check box (1) if it is necessary to disable the automatic calibration of the reader.

    Note

    It is recommended not to unset this check box.

  4. In the Sensitivity Level drop-down list (2) select the sensitivity level:

    • Normal - average sensitivity.

    • High - high sensitivity.

    • Higher - the highest sensitivity.

    • Disabled - disabled.

  5. In the Security Level drop-down list (3) select the fingerprint verification quality level:

    • Lowest (1/1000) - the lowest level.

    • Low (1/10 000) - low level.

    • Normal (1/100 000) - average level.

    • High - (1/1 000 000) - high level.

    • Highest (1/10 000 000) - the highest level.

  6. In the Region In field (4) specify the input region.

  7. In the Region Out field (5) specify the output region.

  8. Click Apply (6) to save the settings.

Note

Attention!

The module requires the 32-bit version of the Microsoft Visual C++ 2008 redistributable package to be installed. If this component is not installed in your system, use the redist/en/x86/vc90redist.exe installer provided in the ACFA PSIM installation package.

Configuring Suprema RealScan control reader is completed.