To configure the Hikvision alarm input, do the following:

  1. Go to the settings panel of the Hikvision 26X Alarm input object.
  2. From the Number drop-down list, in the range from 1 to 4, select the number that corresponds to the number of the alarm input in the Hikvision controller. 
  3. In the Zone name field, enter the name of the alarm input that will be displayed in Axxon PSIM during subsequent readings of the controller configuration.
  4. From the Detector type drop-down list, select the detector type:

    1. Emergency Switch—emergency switch detector (default).
    2. Door Magnetic—door magnetic detector.
    3. Smoke—smoke detector.
    4. Active Infrared—active infrared detector.
    5. Passive Infrared—passive infrared detector.
    6. Glass Break—glass break detector.
    7. Vibration—vibration detector.
    8. Dual Tech. PIR—Dual Technology PIR detector.
    9. Triple Tech. PIR—Triple Technology PIR detector.
    10. Humidity—humidity detector.
    11. Temperature—temperature detector.
    12. Combustible Gas—combustible gas detector.
    13. Other Detector—other detector.
  5. From the Zone type drop-down list, select the zone type:

    1. Instant—instant zone (default).
    2. 24 Hours—permanent zone.
    3. Door Emg. open—open emergency door zone.
    4. Door Emg. shutdown—shutdown emergency door zone.
    5. Shield zone—protected zone.
  6. From the Sensivity drop-down list, select the sensivity value in milliseconds: 10ms (default), 250ms, 500ms, 750ms.

  7. Click the Apply button.