Documentation for ACFA PSIM 1.3.

Previous page Configuration of the Hirsch Velocity integration module  Configuration of the Expansion input Next page

In order to establish connection between ACFA PSIM and Hirsch Velocity ACS Server:

  1. Create the Velocity object under the Computer object.
  2. In the Sql server field, enter the SDL Server instance name (1). The instance must be allowed for remote connection.
  3. In the Database field, enter the Hirsch Velocity database name on the specified SQL Server (2).
  4. In the License field, paste or enter the license key provided by Identiv (3).
  5. Click Sync (4).

As a result, the objects are created in the object tree under the Velocity object according to configuration specified in the database. 

Most of these objects are not configurable. Their settings panels provide information on the device settings (ID, name, address (for readers)), however the settings are not editable. A user can select the icon displayed on the Map for the Expansion input (see Configuration of the Expansion input).

Connection with Hirsch Velocity server is now established.


  • No labels