Documentation for ACFA PSIM 1.3.

Previous page Configuration of the Unicard ACS connection to ACFA PSIM software package  Synchronization of the Server time and the time of the Unicard controller Next page

To send user settings, time zones and schedules to the Unicard controller click the Write accounts button on the settings panel of the Unicard object (1).

In the Card bytes field you may specify the number of bytes the user's card number will take (2).

In the Facility bytes you may specify the number of bytes the user's department code will take (3).  

If changes to the user parameters are to be dynamically sent to the Unicard controller, set the Dynamically checkbox (4).

If changes to the user access levels are to be dynamically updated, set the Update access levels dynamically checkbox. (5

In the Process max time, ms field you may specify the extra time limit to process the data the antipassback mode is on (in this case the data exchange is a little slower) (6).

To send the settings to the Unicard controller, click Write settings (7).  