The Virdi output is configured as follows:

  1. Go to the settings panel of the Virdi Output object that is created on the basis of the Virdi ACU object.
  2. From the PGM number drop-down list, select the output number from 1 to 8.
  3. From the PGM type drop-down list, select the output type:
    • Unusednot used.
    • Matching successtriggers after successful authorization of a user.
    • Matching failedtriggers after an unsuccessful authorization of a user.
    • Scheduled outputworks according to the assigned schedule.
    • Alarm outputtriggers when an alarm is activated.
    • System troublestriggers when a problem occurs in the system, for example, a problem with the battery, a problem with the reader, and so on.
    • Arm/disarm statustriggers when a region becomes armed/disarmed.
    • Fire alarmtriggers when a fire alarm is activated.
    • Silent alarmtriggers when a silent alarm is activated.
    • Open too longtriggers when the door is open for too long.
    • Door forcedtriggers when the door is held by force.
  4. In the Param (dep. on type) drop-down list:
    • if the Matching success or Matching failed output type is selected, then select the door number that will be opened when the corresponding output is triggered: from 1 to 4.
    • if the Alarm output, Fire alarm, or Silent alarm output type is selected, then select the section number in which the alarm will be triggered when the corresponding output is triggered: from 1 to 4.
    • if the Scheduled output output type is selected, then select the schedule number according to which the corresponding output will operate: from 0 to 255.
  5. From the Activation time drop-down list, select the time in seconds for which the output will be activated: from 0 to 255.
  6. Set the Inverted output checkbox if it is necessary to invert the output.
  7. Click the Apply button to apply the settings.