The Virdi reader is configured as follows:
- Go to the settings panel of the Virdi Reader object, which is created on the basis of the Virdi ACU object.
From the Reader number drop-down list, select the reader number from 1 to 12.
Note
The Reader type drop-down list indicates the type of reader. This parameter value cannot be changed.
- From the Open time drop-down list, select the time in seconds for which the door will be open after successful user authentication: from 1s to 255s.
- From the Reader mode drop-down list, select the access grant mode:
- Access only—after successful user authentication, the door assigned to the reader will be open for the time specified in the Open time parameter.
Access + Security—after successful user authentication, the door assigned to the reader will be open for the time specified in the Open time parameter. If the F1 key is pressed on the controller, then after successful user authentication, the partition assigned to the reader and user will be automatically armed. If the partition is already armed, it will be automatically disarmed and the door will be unlocked.
Note
If the Access + Security mode is selected, then user authentication will be performed in Offline mode, regardless of the specified controller authentication mode (see Virdi ACU system settings).
- From the Access mode drop-down list, select the access mode:
- Disabled—mode is disabled.
- Enter—enter.
- Exit—exit.
- Out—from the territory.
- In—to the territory.
- Set the checkboxes next the partitions to which this reader will belong.
- Set the checkboxes next to the doors to which this reader will belong.
- From the Passback type drop-down list, select the antipassback control mode:
- Disabled—mode is disabled.
- Hard Passback (strict)—re-entering the zone is prohibited until one leaves the zone.
- Soft Passback (soft)—repeated access is not prohibited, but in this case, a corresponding event is generated.
Timed Passback (temporary)—strict mode is used during the specified time after entering the zone, and after this time expires, the soft mode is used.
Note
Timed Passback is not available if antipassback is controlled by the Server (see Virdi ACU system settings).
- In the Entry region field, enter an arbitrary name of the region for the entering (maximum four characters). Depending on the selected antipassback control mode, the user will be prohibited or allowed to enter the specified region again (it is necessary for this region name to be indicated at least in two readers).
- In the Exit region field, enter an arbitrary name of the region for the exiting (maximum four characters). Depending on the selected antipassback control mode, the user will be prohibited or allowed to leave the specified region again (it is necessary for this region name to be indicated at least in two readers).
- If the Timed Passback antipassback control mode is selected, then from the Timed APB hour drop-down list, select the time in hours during which the strict mode will be used.
- If the Timed Passback antipassback control mode is selected, then from the Timed APB minute drop-down list, select the time in minutes during which the strict mode will be used.
- If the Timed Passback antipassback control mode is selected, then from the Timed APB second drop-down list, select the time in seconds during which the strict mode will be used.
- From the Entrance and Exit drop-down lists, select the partitions located on the entrance and exit sides of the door, respectively.
- Click the Apply button to apply the settings.