Manufacturer

FoxSec
Tel: (372) 666-14-00
E-mail: info@foxsec.eu

http://www.foxsec.eu/ru/

Integration type

Low-level protocol

Equipment connection

Ethernet


Supported equipment

Equipment

Function

Features

FS9000

Main panel

16 zone inputs (expandable up to 240)
Up to 240 security areas
8 programmable relay outputs (24V/5A/NO/NC) (expandable up to 240)
2880 users
Access only 4- or 6- digit PIN number or PIN number and card
Data communication 10 MB Ethernet
1 separate optically isolated data line for connection of up to 14 in / 8 out expansion modules
64 time and keyboard restriction groups
2500 event memory

FS7002PX (MK)

Door controller

2 doors (up to 4 readers)
2 doors outputs (5A)
2 programmable additional relay output
Up to 1850 card users and 500 last event memory
Compatible card readers: 26-bit Wiegand format reader (PX), magnetic strip reader (MK)

FS7011PX (MK)

Door controller

Access with card and/or user code from R915
Arm using card and/or user code from R915
Access control of one door (it is possible to connect reader, output button, door contact and lock)
Only 4 wires to connect R910 or R915 readers
Firmware updating from PC through CV4USB using WinLoad
Auto opening door by schedule
Information about opened doors and tampers
Timers of door opening and prolonged delay
Manual opening of door by button or by event of RGM output activation
Doors opening while fire alarm
«Safety mode» option (module works with 4 specially programmed access cards while losing connection with panel)
Imbedded impulse AC on 1,5A
Button of power output control
Works with 4-wires 26-bit Wiegand readers

Protection
For parent object.