Documentation for ACFA PSIM 1.3.

Previous page Introduction into Texecom Integration Module Settings Guide  Configuring the Texecom integration module Next page

Manufacturer

Texecom

St. Crispin Way, Haslingden, Lancashire, BB4 4PW, UK

Tel: +44 (0)1706 234800

https://www.texe.com

Integration type

Low-level protocol

Equipment connection

Ethernet, RS-232


Supported equipment

Equipment

Function

Features

Premier Elite 12-W\12-W LINE

Control panel

  • 8 supported wireless zones of the ricochet type
  • 4 wired zones
  • 2 areas
  • 8 user access codes
  • Up to 2 keyboards supported (Premier Elite 12-W only)
  • Integrated LCD Keyboard with Prox Reader (Premier Elite 12-W LINE only)
  • 250 events log
  • Standards PD6662: 2010, EN50131-3, EN50131-5-3 Grade 2 Class II
Premier Elite 24\24-WControl panel
  • 8 zones, can be expanded to 24
  • 2 areas
  • 25 user access codes
  • 500 events log
  • Pluggable Digimodems
  • Interfaces: PSTN / GSM / GPRS / IP (Premier Elite 24 only)
  • Standards EN50131-1, EN50131-3 Grade 3 Class II (Premier Elite 24 only)
  • Standards EN50131-1, EN50131-3 Grade 2 Class II (Premier Elite 24-W only)
  • Supports up to 16 wireless ricochet devices (Premier Elite 24-W only)
  • 4 integrated wired zones (Premier Elite 24-W only)
Premier Elite 48\48-WControl panel
  • 8 zones, can be expanded to 24 (Premier Elite 48 only)
  • Supports up to 32 wireless ricochet devices (Premier Elite 48-W only)
  • 4 integrated wired zones (Premier Elite 48-W only)
  • 4 areas
  • 50 user access codes
  • 500 events log
  • Pluggable Digimodems
  • Interfaces: PSTN / GSM / GPRS / IP (Premier Elite 48 only)
  • Standards PD6662: 2017 Grade 3 Class II (Premier Elite 48 only)
  • Standards PD6662: 2010 Grade 2 Class II (Premier Elite 48-W only)
Premier Elite 88Control panel
  • 8 zones, can be expanded to 88
  • 8 areas
  • 100 user access codes
  • 1000 event log
  • Pluggable Digimodems
  • Interfaces: PSTN / GSM / GPRS / IP
  • Standards PD6662: 2017 Grade 3 Class II
Premier Elite 168Control panel
  • 8 zones, can be expanded to 168
  • 16 areas
  • 200 user access codes
  • 2000 events log
  • Pluggable Digimodems
  • Interfaces: PSTN / GSM / GPRS / IP
  • Standards PD6662: 2017 Grade 3 Class II
Premier Elite 640Control panel
  • Can be expanded to 640 zones
  • 64 areas
  • 1000 user access codes
  • 5000 events log
  • Interfaces: PSTN / GSM / GPRS / IP

Protection
Per 1 control panel.

  • No labels