Previous page General information on ACFA Intellect objects related to the visitor management system  Settings panel of the User object Next page


The picture shows the settings panel of the Department object.

The table gives the description of the Department object settings.

#

 

Parameter name

Method for setting the parameter value

Parameter description

Default value

Value range

1

Identification number field

Automatically

Shows the identification number of the Department object in the system

-

Depends on number of Department objects in the system

2

Name field

Enter the value in the field

Sets the name of the Department object in the system

Department

A line representing a sequence of any symbols
(letters, digits, service characters except < | > symbols), not case-sensitive.

Number of symbols – from 1 to 60.

3

Disable checkbox

Is set in a checkbox

Sets the status (enabled/disabled) of the Department object in the system

False

True - the Department object is enabled and in use

False - the Department object is disabled and not in use

The Access control group

4

Access level dropdown list

Is selected in the list

Sets the department's access level

-

The list of Access level objects created in ACFA Intellect (on the Programming tab or via the VMS) and also Full access and Access forbidden levels.

5

List of access levels

Is selected in the list. To add a new row in the table click left mouse button in any empty space of the table and press "down" arrow on the keyboard.

Sets the department's access level list

-

The list of Access level objects created in ACFA Intellect (on the Programming tab or via the VMS)

The "Rubezh" subsystem group

6

Region dropdown list

Is selected in the list

Sets the Region object for the Rubeg-07 ACS (discontinued)

-

The list of Region objects in the ACFA Intellect software

7

Access level dropdown list

Is selected in the list

Sets the access level for the Rubeg-07 ACS (discontinued)

-

The list of Access level objects created in ACFA Intellect (on the Programming tab or via the VMS) and also Full access and Access forbidden levels.