Supported equipment
Equipment | Function | Features |
BioSmart UniPass/BioSmart UniPass-EX | Standalone access controller | - Maximum number of users 1,000,000
- Maximum number of card codes 1,000,000
- Maximum number of palms 300,000
- Identification time by the veins of the palm (1: 1000) up to 2 s
- Interface for communication with a computer: USB 2.0, Ethernet, (IEEE 802.3, 10BASE-T, IEEE 802.3u, 100BASE-TX, 1000BASETX)
- Reader interface USB 2.0
- Number of readers up to 2
- Number of discrete inputs 6
- Support for verification modes "card + veins of the palm"
- Wiegand interface output
- Number of Wiegand outputs 2
- Simultaneous connection of up to two palm vein readers (BioSmart PV-WM or BioSmart PV-TS)
- Control of two locks or a turnstile
|
BioSmart PV-TS | Reader. Works in tandem with the BioSmart UniPass/BioSmart UniPass-EX access controllers | - Non-contact scanning
- Palm vein scanner optical, infrared
- Scanning distance 40-60 mm
- Built-in RFID card reader
- Card reading range Up to 100 mm
- Communication interface with controller USB 2.0
- Maximum length of USB cable 5 m
- Chassis intrusion detector.
- Built-in Mifare standard plastic card reader
- Built-in HID iClass, HID Prox card reader
- Built-in Legic card reader
|
BioSmart PV-WM | Reader. Works in tandem with the BioSmart UniPass/BioSmart UniPass-EX access controllers | - Non-contact scanning
- Palm vein scanner optical, infrared
- Scanning distance 40-60 mm
- Built-in RFID card reader
- Card reading range Up to 100 mm
- Communication interface with controller USB 2.0
- Maximum length of USB cable 5 m
- Chassis intrusion detector.
- Palm veins are visible only in the IR spectrum
- Identification does not depend on dry / wet and dirty palms.
- Built-in Mifare standard plastic card reader
- Built-in HID iClass, HID Prox card reader
- Built-in Legic card reader
|
USB DCR-PV | Control reader | - Non-contact scanning
- Scanning distance 40-60 mm.
- Scan method Infrared
- Computer interface USB 2.0
- USB cable length 2 m
- High quality image of palm vein pattern
- Comfortable design for palm positioning
- Supports Windows XP, Vista, 7, 8, CE, Linux operating systems
|
BioSmart PV-WTC | Terminal | - Maximum number of users 1,000,000
- Maximum number of palms 300,000
- Time of identification (1: 1000) up to 2 sec.
- Probability of error FAR 0.00008%
- Maximum number of stored events 10,000,000
- Palm vein scanner Optical, infrared
- Built-in EM Marin card reader, frequency 125 kHz
- TFT screen 3.5 ”resolution 320x240
- Keyboard Touchscreen, 12 buttons
- WEB-interface for configuration
- Support for Biosmart relay control unit
- WIEGAND output 26-40 bits
- Computer interface Ethernet (IEEE 802.3, 10BASE-T, IEEE 802.3u, 100BASE-TX)
|
Module licensing