Unable to render embedded object: File (books.jpg) not found.
Go to documentation repository
To configure list of used video cameras do the following:
- Go to the Surveillance Object object setting panel.
- Click the Cameras… button (1). The Add/Edit cameras dialog box opens.
- Move cameras from the list on the left to the list on the right with and buttons (1).
- Select cameras in the list on the right.
- Specify the length of time for which you want to keep video archives, in days (2).
- If titles displaying is required, set the ATM events captions checkbox (3).
- Click the Set for selected cameras listed on the right button (4).
- Repeat steps 4-7 for all cameras in the list on the right.
Set the archive tracking time period (4): For all time or Over period (days). When Over period (days) is selected, the (5) field is enabled to specify the number of days.
Note.
If For all time is selected, the algorithm of decision-making on an alarm for all time is used, even when the video archive is empty.
If Over period (days) is selected, the value entered in field (5) must be greater than or equal to the archive storage time + 1 day.
To take into account the regular voids in the archive, the number of days in the tracking period should be increased by the maximum number of days of regular voids during the archive storage.- Click Apply changes and close button (6).
Note.
Video camera and Captioner ID numbers must be whole integers.
Configuring cameras list is completed.
Overview
Content Tools