Unable to render embedded object: File (books.jpg) not found.
Go to documentation repository
Click the
button (Show Inspector Ctrl+I) to view a special area; the upper part of it shows brief information about the currently selected object.The lower part contains the Fields tab. Information on selected options is shown as columns in the main list of the Log panel workspace.
To receive detailed information about object click it in the Log panel and click the
button (Show detailed information). The Details window will display.Click the
button (Show inspector Ctrl+I) in the Details window to display the special area in the top part of which the information about the current selected object is listed.Note.
If the Owner Panel is in use, then information about only the objects that belong to the owner selected on the Owner Panel is displayed in the Details window. To view the details about all system objects, call this window on the Owner Panel – see Viewing details on alarms for all system objects.
In the bottom part there are 3 tabs: Fields, Archives and Cameras.
Information on selected options will be displayed in view of columns in the main list of Details window.
Data in the Cameras, Disk, GB, Disks, Version, and all fields in the Archives and in Columns tabs, are filled in automatically when packets about technical status are received from objects. If these fields are not filled in for the object, a connection has never been established with the object.
The Camera field shows the number of video cameras at the object.
The Disk, GB field shows the maximum amount of free space on all logical disks to which archive video is recorded.
The Disks field shows the number of logical disks to which archive video is recorded.
The Version field shows the version of ATM Intellect Pro installed at the object.
The fields in the Archives tab show the days of stored video for each camera.
The fields in the Camera tab show the current status of each camera (on/off).
The IP address field displays the IP address of the object.
The First record field shows the date of the very first entry in the video archive from all cameras.
Field Disk temp. shows the temperature of the hard drives separated by a comma if there are several disks.
The CPU Load,% field shows the CPU load as a percentage (updated every 15 minutes).
The Memory, MB field shows the amount of available physical memory in MB.
The Work duration field shows the time of continuous operation of the Intellect.exe\Intellect64.exe process on the object in the format "d hh:mm",
where "d" - day "hh" - hours "mm" - minutes.
Note.
Size of video archive depth for each camera is defined on the ATM-Intellect Pro the following way:
Calculate the real number of days in which the camera performed the data recording in the video archive.
Example. The video surveillance system has been working for 3 days. The camera performed recording to the video archive at the first and third day. At the second day the camera was disabled. For this camera the archive depth is equal to two days.
Click the
button (Show characteristics of devices) to view a special area that describes changes to the indicated fields over time (Camera, Disk GB, Disks, Version, etc.).