Go to documentation repository
Documentation for ATM Intellect 12.0. Documentation for other versions of ATM Intellect is available too.
The table lists all types of alarms that are registered by the monitoring system by default. For the Communication channel alarm group, if ATM Intellect Pro connects to ATM Intellect Workstation over TCP/IP and has connected at least once, the Device field displays the IP address of the object. For ATM Intellect Workstation TC in this case, the IP address of ATM Intellect Workstation is displayed.
Alarm group | Alarm type | Device | Comments |
Communication channel | No connection with object | Communication channel | ATM Intellect Pro connects to ATM Intellect Workstation in client mode. |
No connection with monitoring agent | Local video system | ATM Intellect Pro connects to ATM Intellect Workstation in server mode. | |
Device | Disk failure | 101: Disk name | The Intellect settings specify the disks to which the video archive is written. This alarm occurs when one of these disks does not exist or has an invalid type. Valid disk types include internal and external disks, removable disks, and network disks. |
102: Disk size | Error calculating free disk space. | ||
103: VIDEO folder | No VIDEO folder. | ||
104: Number of disks=0 | There are no disks selected in the Intellect settings for video archive recording. | ||
105: Disk error | An unknown disk error from ATM Intellect Pro. | ||
UPS signal | 1000: PowerChute started 1001: PowerChute stopped 1002: Connection restored 1003: Power restored 1004: Self-test passed 1005: Administrative shutdown 1006: Shutdown cancelled 1007: Battery discharged 1009: Battery replaced 1013: Allowable restart 1014: RTC started 1015: RTC finished 1016: Shutdown in progress 1102: Normal temperature 2000: Power turned off 2001: Shutdown completed 2002: Low power 2003: Low battery 2004: RTC aborted 2007: High power 3000: Connection lost 3001: Restart 3002: Self-test failed 3003: Battery discharged 3004: Battery connection lost 3016: Replace battery 3107: High temperature | ||
Video system software | Software error | Basic software | intellect.exe process terminated. |
Basic software (Video) | video.run process terminated or frozen. | ||
Registry | Registry does not have data required for ATM Intellect Pro to function. | ||
Database | Error connecting to Intellect database. | ||
Archive size | Archive size too small | Archive 1 … Archive N | Storage capacity requirements are not met for camera (see Info on archives). |
Cameras | Camera off | Camera 1 … Camera N | Camera is not working. |
Fire and security alarms | Vibration sensor signal | Vibration sensor | Four sensors (relays), whose names cannot be changed in ATM Intellect Pro: they should be used in accordance with their names ("Vibration Sensor", "Lock", etc.) |
Signal from sensor Lock | Lock | ||
Signal from overheat sensor | Overheat sensor | ||
Signal from additional sensor | Additional sensor | ||
Signal from additional sensor | EXP. SENSOR. SENSOR | 12 sensors (relays), whose names can and should be customized in ATM Intellect Pro, since this name is displayed in the Device column. By default, the string "EXP. SENSOR" is displayed in this column. | |
Scheduled computer restart | Computer | Windows was properly exited before computer restart. | |
Unscheduled computer restart | Computer | Windows was not properly exited before the computer was restarted (power was interrupted). |
Note.
For the Access Control and Detectors alarm groups, no data is sent from ATM Intellect Pro.
There are two types of alarms that are tracked by the monitoring system by default:
- Long;
- Short.
Long alarms have a beginning and an end: "Camera off"/"Camera on", "No connection with object"/"Connected to object".
Short alarms do not have a duration. They only inform about an event, for example, "Vibration sensor triggered" or "Scheduled computer restart", and are not included in the quality measurements for the system.
For short alarms, the End field is immediately filled with the time of the alarm plus one second. Confirmed short alarms are displayed on the control panel for ten minutes.
The following types of alarms are long:
- No connection with object.
- No connection with monitoring agent.
- Disk failure.
- Software error.
- Archive size too small.
- Camera off.