Documentation for ATM Intellect 12.0. Documentation for other versions of ATM Intellect is available too.

Previous page Additional information on alarms  The number of alarms displayed Next page

The table lists all types of alarms that are registered by the monitoring system by default. For the Communication channel alarm group, if ATM Intellect Pro connects to ATM Intellect Workstation over TCP/IP and has connected at least once, the Device field displays the IP address of the object. For ATM Intellect Workstation TC in this case, the IP address of ATM Intellect Workstation is displayed.

Alarm group

Alarm type

Device

Comments

Communication channel                                 

No connection with object

Communication channel

ATM Intellect Pro connects to ATM Intellect Workstation in client mode.

No connection with monitoring agent

Local video system

ATM Intellect Pro connects to ATM Intellect Workstation in server mode.

Device

Disk failure


101: Disk name

The Intellect settings specify the disks to which the video archive is written. This alarm occurs when one of these disks does not exist or has an invalid type. Valid disk types include internal and external disks, removable disks, and network disks.

102: Disk size

Error calculating free disk space.

103: VIDEO folder

No VIDEO folder.

104: Number of disks=0

There are no disks selected in the Intellect settings for video archive recording.

105: Disk error

An unknown disk error from ATM Intellect Pro.

UPS signal

1000: PowerChute started

1001: PowerChute stopped

1002: Connection restored

1003: Power restored

1004: Self-test passed

1005: Administrative shutdown

1006: Shutdown cancelled

1007: Battery discharged

1009: Battery replaced

1013: Allowable restart

1014: RTC started

1015: RTC finished

1016: Shutdown in progress

1102: Normal temperature

2000: Power turned off

2001: Shutdown completed

2002: Low power

2003: Low battery

2004: RTC aborted

2007: High power

3000: Connection lost

3001: Restart

3002: Self-test failed

3003: Battery discharged

3004: Battery connection lost

3016: Replace battery

3107: High temperature

Video system software

Software error

Basic software

intellect.exe process terminated.

Basic software (Video)

video.run process terminated or frozen.

Registry

Registry does not have data required for ATM Intellect Pro to function.

Database

Error connecting to Intellect database.

Archive size

Archive size too small


Archive 1

Archive N

Storage capacity requirements are not met for camera (see Info on archives).

Cameras

Camera off

Camera 1

Camera N

Camera is not working.

Fire and security alarms

Vibration sensor signal

Vibration sensor

Four sensors (relays), whose names cannot be changed in ATM Intellect Pro: they should be used in accordance with their names ("Vibration Sensor", "Lock", etc.)

Signal from sensor Lock

Lock

Signal from overheat sensor

Overheat sensor

Signal from additional sensor

Additional sensor

Signal from additional sensor

EXP. SENSOR. SENSOR

12 sensors (relays), whose names can and should be customized in ATM Intellect Pro, since this name is displayed in the Device column. By default, the string "EXP. SENSOR" is displayed in this column. 


Scheduled computer restart

Computer

Windows was properly exited before computer restart.

Unscheduled computer restart

Computer

Windows was not properly exited before the computer was restarted (power was interrupted).

Note.

Periods of information updating in the interfaces can vary for particular alarm types – see Appendix 1. Data update periods summary.

 For the Access Control and Detectors alarm groups, no data is sent from ATM Intellect Pro.

There are two types of alarms that are tracked by the monitoring system by default:

  1. Long;
  2. Short.

Long alarms have a beginning and an end: "Camera off"/"Camera on", "No connection with object"/"Connected to object".

Short alarms do not have a duration. They only inform about an event, for example, "Vibration sensor triggered" or "Scheduled computer restart", and are not included in the quality measurements for the system.

For short alarms, the End field is immediately filled with the time of the alarm plus one second. Confirmed short alarms are displayed on the control panel for ten minutes.

The following types of alarms are long:

  1. No connection with object.
  2. No connection with monitoring agent.
  3. Disk failure.
  4. Software error.
  5. Archive size too small.
  6. Camera off.