Documentation for ATM Intellect 13.0. Documentation for other versions of ATM Intellect is available too.

Previous page Settings panel of the Search in archive interface object  Appendix 2. Examples of scripts Next page

Settings panel of the ATM Monitoring reports  interface object is given on the figure.

Description of the ATM Monitoring reports object settings panel elements is given in the table.

#

Parameter

Method for setting the parameter value

Description

Type

Default value

Value range

1

Identifier

Automatically

Shows the identification number of the ATM Monitoring reports object in the system

Nonnegative integer

-

>=0

2

Parameter

Enter the value in the field

Shows the identification number of the ATM Monitoring reports object in the system

Latin, Cyrillic letters and service characters

ATM Monitoring reports

A line representing a sequence of any symbols
(letters, digits, service characters apart from > and < symbols), not case-sensitive.

Number of symbols – from 1 to 60.


3

Display

Is selected in the list

Assigns the parent Display object for the ATM Monitoring reports object

Names of Display objects registered in the system

Name of the parent Display object

Depends on the number of the Display objects in the system.

4

X:

Enter the value in the field

Set the X coordinate in the horizontal axis for the upper-left corner of the ATM Monitoring reports interface box

% of the screen width

0

From 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200.

5

Y:

Enter the value in the field

Set the Y coordinate in the vertical axis for the upper-left corner of the ATM Monitoring reports interface box

% of the screen height

50

From 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200.

6

W:

Enter the value in the field

Sets width of he ATM Monitoring reports interface box

% of the screen width

100

From 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200.

7

H:

Enter the value in the field

Sets height of he ATM Monitoring reports interface box

% of the screen height

50

From 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200.

8MonitorSelect from the list

Sets the number of the physical monitor which coordinates are specified. Monitors are numbered in physical order from left to right, top to bottom. Thus, number 1 corresponds to the top-left monitor, regardless of which monitor is the primary or first in the OS numbering.

In the figure, the monitor numbers in the OS are highlighted in gray, and monitor numbers in Intellect are highlighted in red:

Attention! It is recommended to use the same resolution for all monitors in the system. Different resolutions are allowed only if each row of logical monitors is aligned to some sort of boundary (for example, to the top).

Nonnegative integer1From 1 to 16
9Filter by ownersVia the Filters... buttonDisplays selected pairs of users and owners---
10Filter...Click the buttonOpens a dialog box to match owners to users---
11ReportsSet by checkbox

Select reports available in the interface window.

Note. Vehicle LPs report is not in use in ATM Intellect.

BooleanAll checkboxes are set, full access to the Vehicle PLs report is set

Yes – the report button is displayed in the ATM Monitoring Reports interface window.

No – the report button is not displayed in the ATM Monitoring Reports interface window.