Go to documentation repository
Documentation for ATM Intellect 13.0. Documentation for other versions of ATM Intellect is available too.
Settings panel of the Surveillance Object object is given on the figure.
Description of the Surveillance Object object settings panel elements is given in the table.
# | Parameter | Method for setting the parameter value | Description | Type | Default value | Value range |
1 | Identifier | Enter the value in the field | Shows the identification number of the Surveillance object object in the system | Latin, Cyrillic letters and service characters | - | - |
2 | Name | Enter the value in the field | Shows the name of the Surveillance object object in the system | Latin, Cyrillic letters and service characters | Surveillance object | A line representing a sequence of any symbols (letters, digits, service characters excluding characters: underscore "_", backslash "\", angle brackets ">" and "<", single quote "'"). Number of symbols – from 1 to 60. |
3 | ATM-Intellect Pro | Is selected in the list | Assigns the parent ATM-Intellect Pro object for the Surveillance object object | Names of Surveillance object objects registered in the system | Name of the parent ATM-Intellect Pro object | Depends on the number of the ATM-Intellect Pro objects in the system. |
4 | ID | Enter the value in the field | Sets the unique ID number of the ATM machine | Latin, Cyrillic letters and some characters | 386 | A line representing a sequence of any symbols (letters, digits, service characters excluding characters: space " ", underscore "_", backslash "\" and single quote "'"), not case-sensitive. Number of symbols – from 1 to 9. |
5 | TCP port (UPS -SCS) | Enter the value in the field | Sets the port on which to "listen" for UPS messages | Nonnegative integer | 8888 | from 1 to 60000 |
6 | Transmitting... | Click the button | Opens a dialog box with settings for configuring the communication between ATM-Intellect Pro and ATM-Intellect Workstation | - | - | - |
7 | Printer... | Click the button | Opens a dialog box for configuration of ATM receipts captioning. | - | - | - |
8 | Cameras | Using the Cameras... button | Displays the list of cameras whose state and archives are monitored by ATM-Intellect Pro and operating with which shall be available from ATM-Intellect software interface. | - | - | - |
9 | Cameras... | Click the button | Opens a dialog box for adding cameras for monitoring their status | - | - | - |
10 | Displaying time (sec.) | Is selected in the list | Sets duration of captions displaying on video image beginning at the moment of corresponding event appearing from the secured object (ATM) | Seconds | 10 | 5, 10, 15, 20, 30, 45, 60, 90, 120, 200 |
Date and time | Is set in a checkbox | Specifies if it is necessary to include event date and time into the captions | Boolean | True | True – date and time are included into the captions False – date and time are not included into the captions | |
ATM number | Is set in a checkbox | Specifies if it is necessary to include into the captions the number of ATM from which the event came | Boolean | True | True – ATM number is included into the captions False – ATM number is not included into the captions | |
Card status | Is set in a checkbox | Specifies if it is necessary to include data on card status into the captions | Boolean | True | True – card status is included into the captions False – card status is not included into the captions | |
Amount | Is set in a checkbox | Specifies if it is necessary to include operation amount into the captions | Boolean | True | True – amount is included into the captions False – amount is not included into the captions | |
Card number | Is set in a checkbox | Specifies if it is necessary to include card number into the captions | Boolean | True | True – ATM number is included into the captions False – ATM number is not included into the captions | |
Mask | Is set in a checkbox | Specifies if it is necessary to apply mask to a card number when displaying in in the captions | Boolean | True | True – card number is masked False – card number is fully displayed | |
11 | Sensors | Using the Add, Edit and Delete buttons | Displays IDs and types of sensors whose state is monitored by ATM-Intellect Pro and on whose triggering video data are sent to the ATM-Intellect Workstation. | - | - | - |
12 | Add... | Click the button | Opens a dialog box for adding a sensor. In this dialog box one can also setup video data sending on the sensor triggering | - | - | - |
13 | Edit... | Click the button | Opens a dialog box for editing the sensor. This dialog box is similar to the one for adding a sensor | - | - | - |
14 | Delete | Click the button | Deletes sensor from the list | - | - | - |