Go to documentation repository
Documentation for ATM Intellect 13.0. Documentation for other versions of ATM Intellect is available too.
StateUPS utility (exe-file and ini-file) is installed with ATM-Intellect Pro and placed to the <Intellect software installation>/Vhost/UPS/.
Note.
Files from the <Intellect software installation>/Vhost/UPS/Ext directory will look for the ini settings file in the same directory as the StateUPS utility.
Configure the file StateUPS.ini, which is located in this directory:
- Address – IP address of the computer on which ATM Intellect Pro is installed. The default value is 127.0.0.1. If you are installing StateUPS on the same computer on which ATM Intellect Pro is installed, you do not need to change this setting.
- Port – the TCP port on which StateUPS sends messages from the UPS. The value of this setting must match the corresponding setting in ATM Intellect Pro, TCP port (UPS-SCS) (see Setting the port used to listen for messages from the UPS and Smart Card Service ATMs).
If the StateUPS utility is to be used on another computer, do the following:
- Create "HKLM\SOFTWARE\BitSoft\VHOST\VHostService" section for 32-bit OS ("HKLM\SOFTWARE\Wow6432Node\BitSoft\VHOST\VHostService" for 64-bit) in the registry on this computer.
- In this section, create the "FolderLog" parameter. In the "FolderLog" parameter specify the path where the UPS folder will be created containing ini-file. For example, if the folder is C:\EVUPS, then "FolderLog" = "C:\EVUPS\"
- In the specified folder, for example, C:\EVUPS, create the UPS sub-folder and copy the StateUPS.ini into it.
Overview