Setting up the VIT program module is performed in the following way:

  1. Go to the Hardware tab in the System settings dialog window (1).
  2. In the objects tree on the Hardware tab select the VIT object, corresponding to the set VIT program module (2). The settings panel of the selected object will open on the right of the window.
  3. Set the Zooming check box to increase the plate recognizing speed on mega-pixel vedio cameras without loss of recognizing quality (3).

    Note.

    This check box is relevant when the value of the Zone width parameter is more than 150 pixels (see Setting up the LPR channel detector section). The recognizing speed is increasing:

    • 2 times if the value of the Zone width parameter is more than 150 pixels;
    • 4 times if the value of the Zone width parameter is more than 400 pixels;
    • 8 times if the value of the Zone width parameter is more than 800 pixels.
  4. Click Apply to save the changes (4).

Setting up the VIT program module is completed.