All events received by Auto-Intellect from Uragan are saved in the SQL database. The database may become too large with time, which increases the CPU load. To limit the database size, the storage period of the events in the database should be specified. This defines the archive depth.

Note.

If the specified archive depth is smaller than it has been before, the database will reduce gradually.

To set up the archive depth, do the following.

  1. In the System Settings dialog window, open the Hardware tab.
  2. In the object tree of the Hardware tab, select the LPR channel, corresponding to the activated program module (see Activating the program module, used for identifying the plates section, 2).The settings panel of the selected object will open on the right side of the window.
  3. In the Archive size, days field, enter the archive depth in days (3).
  4. Click Apply (4).

The archive depth is set.