Go to documentation repository
Documentation for Auto Intellect 5.6. Documentation for other versions of Intellect is available too.
The Traffic violations detection module object settings panel contains the following interface elements:
The following table describes the elements of the Traffic violations detection object settings panel.
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
---|---|---|---|---|---|---|
1 | Traffic lights signal dropdown list | Selecting the value in the list | Selecting «Sensor/Detector» object, by signal of which traffic light is detected | List of accessible «Sensor/Detector» objects | no | Depending on number of accessible «Sensor/Detector» objects |
2 | Alarm direction dropdown list | Selecting the value in the list | Selecting the signal of traffic light detection on which the traffic violations detection is to be responded | List of accessible directions | Basic | Basic - use the basic signal of the traffic light Left - use the left arrow of the traffic light Right - use the right arrow of the traffic light |
3 | Draw a stop line checkbox | Setting check box | Draw a stop line on video in front of traffic light function activation | Boolean type | no | Yes – drawing a stop line function is active |
4 | Stop line settings button | Clicking | Access to stop line settings | - | - | - |
5 | Setting violation areas button | Clicking | Access to stop line settings | - | - | - |
6 | Delay in violation registering field | Setting the value in the field | Set period after which the running a red light or stop will be considered as a violation | Millisecond | 1000 | 0-99999 |
7 | Time of stop for recording field | Setting the value in the field | Set period that determines the time interval during which the vehicle should stay still while registering the Stop over crosswalk line violation | Millisecond | 3000 | 0-99999 |
8 | Add.photos: field | Setting the value in the field | Set the number of photos made before the licence plate fixing and after its going out the control zone | Whole nonnegative number | 2 | 0-99 |
9 | Interval: field | Setting the value in the field | Set period that determines the time interval between saving additional photos | Millisecond | 1000 | 0-99999 |
10 | Number of pictures to trace alarm: field | Setting the value in the field | Specifying number of photos which will be stored from the moment of LP recognizing on the base recognizer to the moment of LP recognizing on the additional recognizer | Whole nonnegative number | 3 | 0-99 |
Additional recognizers table | ||||||
11 | LPR channel column | Selecting the value in the field | Selecting the additional LPR channel if it's required to use additional recognizers along with the base recognizer | List of accessible "LPR channel" objects | - | Depending on number of accessible LPR channel objects |
Sensor column | Selecting the value in the field | Selecting sensor from which events about traffic light operation will be received | List of accessible "Sensor" objects | - | Depending on number of accessible Sensor objects | |
State column | Selecting the value in the field | Selecting event from the sensor on which violation will be fixed | - | - | Active (on) – sensor is closed Normal (off) – sensor is opened | |
Alarm type column | Selecting the value in the field | Selecting type of violation which will be fixed in result of joint operation of additional and base recognizers | - | - | Marking violation Red light violation |