Documentation for DetectorPack PSIM 1.0.1.

Previous page Functionality of the Queue length detection module  Configuring the Queue length detection module Next page

The requirements for the cameras that will work with the Queue length detection module are listed in the following table.

Camera

  • Resolution: 720x576 (CIF4), using of 360x288 (CIF1) is acceptable; oversize images are reduces until CIF4.
  • Fps: not less than 6.
  • Color: analytics works with grey and color images.
  • Camera must be rigidly fixed.

Lighting

  • The best working of detection is archived at medium lighting. In conditions of insufficient (night) or excessive (exposure) lighting, the quality of analytics can be reduced.
  • Sharp changes of lighting can lead to short-time invalid analytics working.

Scene and camera angle

  • The best position – camera "looks" to the scene vertically down. The better this requirement, the carefully the received estimation.
  • Sizes of camera field of view: 3x3m is minimal (6x6 people), 4x4m is optimal (8x8 people), 8x8m is maximal (16x16 people).
  • Background is static and is not changed sharply.
  • Analytics can work inappropriately on specular surfaces and in case of sharp shadows from moved objects.
  • Analytics can work inappropriately in case of in the camera field of view there are periodic movements of background objects (trees, working TV, etc.).

Objects image

  • Image quality: the image is to be clear, without visible defects from reducing procedure.
  • Permissible size of a person (the area of a rectangular track around a person) as a percentage of the frame area: from 0.25% to 10%.
  • No labels