Documentation for DetectorPack PSIM 1.0.1.

Previous page Configuring the Neurotracker module  Examples of configuring neural tracker for solving typical tasks Next page

The neurotracker track counter is configured as follows:

  1. Go to the Track counter object settings panel, which is created on the basis of the Neurotracker object.
  2. On the video image, specify the surveillance area, within which the track counter will count the objects:
    1. Click the Settings button (1). As a result, the Detection settings window will open.
    2. Click the Stop video button (1) to capture a frame of the video image.
    3. Click the Area of interest button (2) and select the area, within which the track counter will count the objects (3).

      Note

      To delete the selected area, click the  button.

    4. Click the OK button (4).
  3. If the Generate event only when the number is changed checkbox (4) is not set, then from the Counter period drop-down list (2), select the counter period time unit: seconds, minutes, hours, days. Then in the field (3), specify the time in which the event containing the total number of objects recorded for a given time period will be generated.
  4. Set the Generate event only when the number is changed checkbox (4) if it is necessary to generate events only when the number of recorded objects changes.

    Note

    If this checkbox is set, the Counter period field becomes inactive, and the specified value of the counter period is ignored.

  5. If objects are lost during the track counter operation, then for more accurate counting, set the Set number of frames for counting checkbox (5) and in the field (6), enter the number of frames that will be analyzed to calculate the average objects number.

    Note

    • This feature works only if the Generate event only when the number is changed checkbox is set.
    • The value of the number of frames for counting is selected experimentally depending on the neural network used. Recommended values are: 3, 5, 7, 9.
  6. Click the Apply button (7).

The neurotracker track counter is configured.

Note

To display the events that were generated by the neurotracker track counter in the Event Viewer, it is necessary to configure a filter for the track counter. For details, see Configuring event filters for displaying in the Event viewer.

  • No labels