All events from the DetectorPack PSIM software modules come from the CAM object that corresponds to the Camera system object.
You can use events of software modules in Axxon PSIM scripts to launch the procedures when a corresponding event occurs (see Guide for creating scripts (programming)).
Event format:
CAM|"_id_"|"_command_"|"_parameters_"
Events description:
Event | Description | Software module used |
---|---|---|
NEW_OBJECT | Appearance of a new track (object) | Neurotracker |
OBJECT_LOST | Disappearance of a track (object) | Neurotracker |
CURRENT_OBJECTS | Event for the GET_STATUS command | Neurotracker |
List of event parameters:
Parameters | Parameters description |
---|---|
cam<> | id of the software module that generates an event |
fraction<> | Millisecond timestamp of event |
new_id<> | id of a new track (object) |
detector_id<> | id of the detection tool |
owner<> | Server name |
date<> | Date of event |
label<> | id of object class |
guid_pk<> | id of event (randomly generated for each event) |
core_global<> | When an event is generated, all CORE objects in the distributed system are notified |
time<> | Time of event |
lost_id<> | id of a disappeared track (object) |
y1.0<>... | 1—upper left corner of the track frame (object), 0—sequence number of a track (object) in the event, <>—y coordinate |
y2.0<>... | 2—lower right corner of the track frame (object), 0—sequence number of a track (object) in the event, <>—y coordinate |
x1.0<>... | 1—upper left corner of the track frame (object), 0—sequence number of a track (object) in the event, <>—x coordinate |
x2.0<>... | 2—lower right corner of the track frame (object), 0—sequence number of a track (object) in the event, <>—x coordinate |
id.0<>... | 0—sequence number of a track (object) in the event, <>—object id |
id.count<> | Current number of tracks (objects) |
mdparam0<> | Parameters of the track border, where 0—sequence number of a track, <>—track coordinates, display angle and track id. For example, for mdparam0<35-44-16-35-360-6>, 35-44-16-35—track coordinates, 360—display angle, 6—track id |
show<> | Drawing a border on live video: 0—do not draw, 1—draw |
color0<> | Border color, where 0—sequence number of a track, <>—border color, vmda_color—parameter that specifies border color of the VMDA detection. If you don't specify the parameter, border color is red by default |
lifetime<> | Border lifetime in milliseconds |
type<> | Type of detection source: 0—VMDA, 10—Detector Pack |
parent_id<> | Id of parent detection tool: for the VMDA detection, this is the id of the tracker or Neurotracker. For the Pose detection tool, this is the id of the basic person tracker |
type_rect<> | Type of track border |
persistent_exist<> | Presence of tracks that must be saved to the archive in the MD_INFO command. 0—no tracks to save to the archive |
persistent0<> | Track that must be saved to the archive, where 0—sequence number of a track, <>—track id |
iit_object_id0<> | Track id, where 0—sequence number of a parameter, <>—track id |
tss<> | Current time from which the lifetime<> of a border is calculated, for example, tss<30-06-2023 12:02:40.000> |