Settings panel of the Monitoring reports interface object is given on figure.
Description of the Monitoring reports object settings panel elements is given in table.
# | Name | Method for setting the parameter value | Description | Type | Default value | Value range |
---|---|---|---|---|---|---|
1 | Identifier | Automatically | Shows the identification number of the Monitoring reports object in the system | Nonnegative integer | - | >=0 |
2 | Name | Enter the value in the field | Shows the identification number of the Monitoring reports object in the system | Latin letters and service characters | Monitoring reports | A line representing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive. |
3 | Display | Is selected in the list | Assigns the parent Display object for the Monitoring reports object | Names of Display objects registered in the system | Name of the parent Display object | Depends on the number of the Display objects in the system |
4 | X: | Enter the value in the field | Set the X coordinate in the horizontal axis for the upper-left corner of the Monitoring reports interface window | % of the screen width | 0 | From 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200 |
5 | Y: | Enter the value in the field | Set the Y coordinate in the vertical axis for the upper-left corner of the Monitoring reports interface window | % of the screen height | 50 | From 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200 |
6 | W: | Enter the value in the field | Sets width of the Monitoring reports interface window | % of the screen width | 100 | From 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200 |
7 | H: | Enter the value in the field | Sets height of the Monitoring reports interface window | % of the screen height | 50 | From 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200 |
8 | Monitor | Select from the list | Sets the number of the physical monitor which coordinates are specified. Monitors are numbered in physical order from left to right, top to bottom. Thus, number 1 corresponds to the top-left monitor, regardless of which monitor is the primary or first in the OS numbering. In the figure, the monitor numbers in the OS are highlighted in gray, and monitor numbers in Axxon PSIM are highlighted in red: Attention! It is recommended to use the same resolution for all monitors in the system. Different resolutions are allowed only if each row of logical monitors is aligned to some sort of boundary (for example, to the top) | Nonnegative integer | 1 | From 1 to 16 |
9 | Filter by owners | Via the Filter... button | Displays selected pairs of users and owners | - | - | - |
10 | Filter... | Click the button | Opens a dialog box to match owners to users | - | - | - |
11 | Reports | Set the check box | Select reports available in the interface window | Boolean | All check boxes are set, full access to the Vehicle PLs report is set | Yes – the report button is displayed in the Monitoring reports interface window No – the report button is not displayed in the Monitoring reports interface window |