Settings panel of the Monitoring reports interface object is given on figure.


Description of the Monitoring reports object settings panel elements is given in table.

#

Name

Method for setting the parameter value

Description

Type

Default value

Value range

1

Identifier

Automatically

Shows the identification number of the Monitoring reports object in the system

Nonnegative integer

-

>=0

2

Name

Enter the value in the field

Shows the identification number of the Monitoring reports object in the system

Latin letters and service characters

Monitoring reports

A line representing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive.
Number of symbols – from 1 to 60

3

Display

Is selected in the list

Assigns the parent Display object for the Monitoring reports object

Names of Display objects registered in the system

Name of the parent Display object

Depends on the number of the Display objects in the system

4

X:

Enter the value in the field

Set the X coordinate in the horizontal axis for the upper-left corner of the Monitoring reports interface window

% of the screen width

0

From 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200

5

Y:

Enter the value in the field

Set the Y coordinate in the vertical axis for the upper-left corner of the Monitoring reports interface window

% of the screen height

50

From 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200

6

W:

Enter the value in the field

Sets width of the Monitoring reports interface window

% of the screen width

100

From 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200

7

H:

Enter the value in the field

Sets height of the Monitoring reports interface window

% of the screen height

50

From 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200

8MonitorSelect from the list

Sets the number of the physical monitor which coordinates are specified. Monitors are numbered in physical order from left to right, top to bottom. Thus, number 1 corresponds to the top-left monitor, regardless of which monitor is the primary or first in the OS numbering.

In the figure, the monitor numbers in the OS are highlighted in gray, and monitor numbers in Axxon PSIM are highlighted in red:

Attention! It is recommended to use the same resolution for all monitors in the system. Different resolutions are allowed only if each row of logical monitors is aligned to some sort of boundary (for example, to the top)

Nonnegative integer1From 1 to 16
9Filter by ownersVia the Filter... buttonDisplays selected pairs of users and owners---
10Filter...Click the buttonOpens a dialog box to match owners to users---
11ReportsSet the check boxSelect reports available in the interface windowBooleanAll check boxes are set, full access to the Vehicle PLs report is set

Yes – the report button is displayed in the Monitoring reports interface window

No – the report button is not displayed in the Monitoring reports interface window