Documentation for Monitoring PSIM 1.0 (english)

Previous page Settings panel of the Agent Of Control object  Settings panel of the Server Of Control object Next page

Settings panel of the Partition Of Control object is given on figure.

Description of the Partition Of Control object settings panel elements is given in table.

#

Name

Method for setting the parameter value

Description

Type

Default value

Value range

1

Identifier

Enter the value in the field

Shows the identification number of the Partition Of Control object in the system

Latin letters and service characters

-

-

2

Name

Enter the value in the field

Shows the name of the Partition Of Control object in the system

Latin letters and service characters

Partition Of Control

A line representing a sequence of any symbols (letters, digits, service characters excluding characters: underscore "_", backslash "\", angle brackets ">" and "<", single quote "'").
Number of symbols – from 1 to 60

3

Agent Of Control

Is selected in the list

Assigns the parent Agent Of Control object for the Partition Of Control object

Names of Agent Of Control objects registered in the system

Name of the parent Agent Of Control object

Depends on the number of the Agent Of Control objects in the system

4

ID

Enter the value in the field

Sets the unique ID number for the object where Agent of Control is installed

Latin letters and some characters

386

A line representing a sequence of any symbols (letters, digits, service characters excluding characters: space " ", underscore "_", backslash "\" and single quote "'"), not case-sensitive.
Number of symbols – from 1 to 9

5

TCP port (UPS)

Enter the value in the field

Sets the port on which to "listen" for UPS messages

Nonnegative integer

8888

from 1 to 60000

6

Transmitting...

Click the button

Opens a dialog box with settings for configuring the communication method between Agent of control and Server of control

-

-

-

7

Monitoring...

Click the button

Opens a dialog box for configuring alarm groups

-

-

-

8Video data...Click the buttonOpens a dialog box for setting video data transferring configurations---

9

Cameras

Using the Cameras... button

Displays the list of cameras whose state and archives are monitored by Agent of Control and operating with which shall be available from Monitoring PSIM software interface

-

-

-

10

Cameras...

Click the button

Opens a dialog box for adding cameras for Monitoring PSIM

-

-

-

11

Sensors

Using the Add, Edit and Delete buttons

Displays IDs and types of sensors whose state is monitored by Agent of Control and on whose triggering video data are sent to the Server of Control

-

-

-

12

Add...

Click the button

Opens a dialog box for adding a sensor. In this dialog box one can also setup video data sending on the sensor triggering

-

-

-

13

Edit...

Click the button

Opens a dialog box for editing the sensor. This dialog box is similar to the one for adding a sensor

-

-

-

14

Delete

Click the button

Deletes sensor from the list

-

-

-