You can add IP devices in bulk by importing their parameters from a CSV file.

Attention!

You have to disable the UAC first.

Do the following:

  1. Create a CSV file with devices listed as follows:

    IP address, Port, Manufacturer, Model, Login, Password, Identifier, Object name

    For example:

    10.0.12.245, 80, Bosch, Dinion IP starlight 8000 MP, service, Admin12345!, 1441, Camera 1
    10.0.12.246, 80, Bosch, Dinion IP starlight 8000 MP, service, Admin12345!, 1442, Camera 2
    10.0.12.247, 80, Bosch, Dinion IP starlight 8000 MP, service, Admin12345!, 1443, Camera 3

    Attention!

    The manufacturer and model of the device must be specified exactly as in the list of supported devices.

    Note

    The CSV file must be UTF-8 or UTF-32 encoded so the object name in the Axxon Next VMS is properly displayed.

  2. Drag & drop the created file to the field in IP Device Discovery Wizard  in Axxon Next.

The devices will be added to the configuration.