After adding a camera to the map, perform the following actions:

  1. Drag the video camera's icon to the place on the map that represents the camera's actual location at the site (1).
  2. On the map, use the corner nodes to adjust the video camera's field of view to match the actual situation at the site (2).

    Important!

    For ceiling-mounted fisheye cameras (see 어안 카메라 구성), you are advised to set a 360° field of view. If you do so, the video from the camera will be directly available in the specified area:

    To enable this feature on cameras with ImmerVision lenses, PTZ display mode must be chosen (see 어안 카메라 구성)

  3. Configure the area for video display:

    Important!

    The video display area is not available for ceiling-mounted fisheye cameras
  • using the points at the base (3), set the size of the area (left-click and drag the cursor)
  • using a third point (4) to change the tilt of the area

    Note

    You can switch map display to flat while working with the Map (see Customizing an Interactive Map).

  • using the slider in the lower-right corner to set the default transparency of the area

Configuration of the camera in standard map viewing mode is complete.