To configure the Crowd estimation VA, do the following:
- Go to the Detectors tab.
Below the required camera, click Create… → Category: Retail → Crowd estimation VA.
By default, the detector is enabled and set to count crowds of people.
If necessary, you can change the settings of the detector parameters given in the table:
Parameter | Value | Description |
---|---|---|
Object features | ||
Record mask to archive | Yes | By default, the recording of the mask to the archive is disabled. To record the sensitivity scale of the detector to the archive (see Displaying information from a detector (mask)), select the Yes value |
No | ||
Video stream | Main stream | If the camera supports multistreaming, select the stream for which detection is needed |
Other | ||
Enable | Yes | By default, the detector is enabled. To disable, select the No value |
No | ||
Name | Crowd estimation VA | Enter the detector name or leave the default name |
Decoder mode | Auto | Select a processing resource for decoding video. When you select a GPU, a stand-alone graphics card takes priority (when decoding with Nvidia NVDEC chips). If there is no appropriate GPU, the decoding will use the Intel Quick Sync Video technology. Otherwise, CPU resources will be used for decoding |
CPU | ||
GPU | ||
HuaweiNPU | ||
Mode | CPU | Select a processor for the operation (see Selecting Nvidia GPU when configuring detectors) Attention! If you specify other processing resource than the CPU, this device will carry the most of computing load. However, the CPU will also be used to run the detector. |
Nvidia GPU 0 | ||
Nvidia GPU 1 | ||
Nvidia GPU 2 | ||
Nvidia GPU 3 | ||
Number of alarm objects | 1 | Specify the number of objects at which an event occurs. The value must be in the range [0, 10000] |
Number of frames processed per second | 0.017 | Specify the number of frames for the detector to process per second. The value must be in the range [0.016, 100] |
Trigger upon count | Greater than or equal to threshold value | Select when you want to generate events. The Crowd estimation VA will generate events from the threshold value set in the Number of alarm objects field |
Less than or equal to threshold value | ||
Change in readings | ||
Type | Crowd estimation VA | Name of the detector type (non-editable field) |
By default, the entire frame is the detection area. In the preview window, you can specify the detection areas using the anchor points Configuring a detection area). (see
To save the parameters of the detector, click the Apply button. To cancel the changes, click the Cancel button.
It is possible to display the sensor and the number of objects in the monitored area in the Surveillance window on the layout (see Displaying the number of detected objects).