To create the Hands up detector, do the following:

  1. Create the Human pose detector (see Configuring the Human pose detector).
  2. Below the Human pose detector, click Create…  Hands up detector.

By default, the Hands up detector generates an event if there is a person with both hands raised in a specified area.

If necessary, you can change the detector parameters. The list of parameters is given in the table:

ParameterValueDescription
Other
EnableYesThe detector is enabled by default. To disable the detector, select the No value
No
Name Hands up detectorEnter the detector name or leave the default name
TypeHands up detectorName of the detector type (non-editable field)
Basic settings
Event generation conditionBoth handsSelect this value if you want the detector to generate an event only when a person has both hands raised
One handSelect this value if you want the detector to generate an event only when a person has either left or right hand raised
Only leftSelect this value if you want the detector to generate an event only when a person has one selected hand raised
Only right
Left handSelect this value if you want the detector to generate an event only when a selected hand is raised
Right hand
Number of measurements in a row to trigger detection2

Specify the minimum number of frames with a person with a hand/hands raised for the detector to generate an event. The value must be in the range [1, 20].
The recommended (default) value is 2.
Increasing the value can help eliminate false events, but increases the risk of skips. 
Decreasing the value can help reduce skips, but increases the probability of false events

Note

  • The Hands up detector works in the areas for detection and skip areas specified in the Human pose detector (see Configuring the Human pose detector).
  • For convenience of configuration, you can "freeze" the frame. Click the button. To cancel the action, click this button again.
  • The area for detection is displayed by default. To hide it, click the button. To cancel the action, click this button again.

To save the parameters of the detector, click the Apply  button. To cancel the changes, click the Cancel  button.

Configuration of the Hands up detector is complete.