Documentation for Axxon One 2.0. Documentation for other versions of Axxon One is available too.

Previous page Functions of the Signal detector  Tampering detector Next page

To configure the Signal detector, do the following:

  1. Go to the Detectors tab.

  2. Below the required camera, click Create… → Category: Service → Signal detector.

By default, the detector is enabled and set to detect signals.

If necessary, you can change the detector parameters. The list of parameters is given in the table:

ParameterValueDescription
Other
EnableYesThe detector is enabled by default. To disable the detector, select the No value
No
NameSignal detectorEnter the detector name or leave the default name
TypeSignal detectorName of the detector type (non-editable field)
Basic settings
Alarm end delay10Enter the time in seconds during which the generation of an event won't stop after the noise stops. If noise is detected again within the specified time, it is considered as one event
Percentage of noise in audio stream2Specify the threshold value of noise in the audio stream as a percentage. If the value is exceeded, the detector generates an event. You must select the value empirically in the range [0, 100]

To save the parameters of the detector, click the Apply  button. To cancel the changes, click the Cancel  button.

Configuration of the Signal detector is complete.