Documentation for Axxon One 2.0. Documentation for other versions of Axxon One is available too.

Previous page Configuring the Human pose detector sub-detectors  Configuring the Person down detector Next page

On the page:



Configuring the parameters

To create the Sitting person detector, do the following:

  1. Create Human pose detector (see Configuring the Human pose detector).
  2. Below the Human pose detector, click Create…  Sitting person detector.

By default, the Sitting person detector generates an event if a sitting person is detected in the specified area.

If necessary, you can change the detector parameters. The list of parameters is given in the table:

ParameterValueDescription
Other
EnableYesThe detector is enabled by default. To disable the detector, select the No value
No
Name Sitting person detectorEnter the detector name or leave the default name
TypeSitting person detectorName of the detector type (non-editable field)
Basic settings
Number of measurements in a row to trigger detection2

Specify the minimum number of frames with the corresponding pose or behavior for the detector to generate an event. The value must be in the range [1, 20].
The recommended (default) value is 2.
Increasing the value can help eliminate false events, but increases the risk of skips. 
Decreasing the value can help reduce skips, but increases the probability of false events

To save the parameters of the detector, click the Apply button. To cancel the changes, click the Cancel button.

Configuring the frame perspective 

If a camera angle doesn't meet the requirements (see Video stream and scene requirements for the Human pose detector and its sub-detectors), this can result in false events. In this case, we recommend configuring the frame perspective using the leveling rods. 

For this, do the following:

  1. In the preview window, click the button.
  2. Specify the size of the same person in different parts of the frame by eye:
    • To create a leveling rod, left-click the video image to add two anchor points.
    • Set at least three calibration rods. The lower anchor points of any three rods must not be located on the same line (horizontal, vertical, slanting, and so on).

    • The size of the leveling rod must be about the average height of a person at this part of the frame.
    • You can resize the rod by stretching its anchor points . You can move it on screen by dragging and dropping.

      Attention!

      When you set up leveling rods, the following conditions must be met:

      1. the rods that are located at the same distance from the camera lens must be of the same size;
      2. the feet of the rods must be located on the same surface (for example, floor);
      3. in complex scenes, we recommend adding more than three rods to increase the accuracy of the detection;

      4. in the parts of the frame where the lens vertical distortion is observed, the rods must be parallel to the nearest vertical objects (for example, door, wardrobe);

      5. for portrait-oriented scenes (such as corridor, shopping aisle, warehouse aisle, and so on), the arrangement of the rods must form triangles.

      Note

      • For convenience of configuration, you can "freeze" the frame. Click the button. To cancel the action, click this button again.
      • The area for detection is displayed by default. To hide it, click the button. To cancel the action, click this button again.
      • To delete a rod, click the button.
  3. Click the Apply button.

Configuration of the Sitting person detector is complete.

  • No labels